4
in case of the resignation from the assembly of manual control buttons, remember about bridging "STOP"
clamps. The lack of the bridge will make any move of motors impossible.
4
in case of the resignation from the assembly of the photocell, bridge PHOTO1 and/or PHOTO2 inputs with the
COM clamp
7.2. Final tests consist of the following stages
7.2.1. Move direction control
Check if at controlling the function OPENING, automation physically moves towards opening. If the
movement is directed towards closing, or any movement is missing, inspect connections and/or conduct the
procedure of the programming again.
7.2.3. Initial security control
If photocells are installed, it is necessary to manually breach FOTO1 photocell, at breaching LED FT1 diode
in the driver should go out. Do the same for FOTO2 photocell if it is installed ( JOL LED diode). Firstly FOTO2
Photocell must be activated, see tab. 1. In the sleep mode, when optical barriers are not breached, 2 red LED diodes
should light (2 first from the right side)
7.2.4. Control of functions controlling the motor move
4
Check STEP BY STEP function by using the remote control button or manual P/P button. After consecutive
impulses from the button a sequence compatible with table 1 settings should take place.
4
Check CLOSING function by using remote control button manual PC button. With the gate entirely or partly
opened, give impulse from CLOSING button - the motor should make a move towards closing
4
Sprawdziæ funkcjê ZAMYKANIE u¿ywaj¹c przycisku pilota lub przycisku rêcznego PC. Przy ca³kowicie lub
czêœciowo otwartej bramie, podaæ impuls z przycisku ZAMYKANIE - si³ownik powinien wykonaæ ruch w
kierunku zamykania.
4
Check STOP function by using manual button. During motor move in direction towards closing or opening,
give impulse from STOP button – the drive should stop.
7.2.5.Control of overloading protection
After intitiating closing the gate physically block the move of the gate leaf. Do it into the safe way, keeping
increased caution. Assess the power needed for such blocking the gate so that the driver automatically stops the
move of the gate. Repeat the process in opening direction. If necessary correct the adjusted value of power with PW
potentiometer (make it smaller if it you had to use too great power to stop the gate, or increase if it was possible to
stop the gate too easily). After correcting the setting, conduct the above test again. Remember about the fact that
the gate can resist harder to the motor in the winter period, so the adjusted value of the overload must be big
enough, not to stop the gate spontaneously. At the same time remember about the safety of users and do not adjust
the power parameter to the maximum value. Power necessary for blocking the gate which automatic turning off the
motor must be small enough so that the gate does not pose a threat of injury (especially of a child).
If the overload protection does not provide satisfying effects, apply other protection devices (e.g.
safety edges, additional photocells, etc.).