1. Used terms
4
motor power adjustment - In most cases the maximum operation power of the motor is not required. For
security reasons and to protect the structure of the gate against too powerful forces which can lead to its
damaging, it is recommended to set the optimum power of motors.
4
manual control - controlling with the use of buttons connected by wires with the motor clamps.
4
motor opening time - time required for full opening of the gate powered by the motor.
4
motor closing time - time required for full closing of the gate powered by the motor.
4
auto-closing - automatic introduction of closing the motor function after the time specified in the program of
the driver. Time, after which automatic closing shall start, is counted from the moment of stopping the gate.
4
auto-photo closing - automatic introduction of closing the motor function after the time specified in the
program of the driver. Time, after which automatic closing shall start, is counted from the moment of stopping
the gate.
4
photo-test - automatic check of the photocells operation just before the gate move start.
4
motor overload - increase in the value of the electricity taken by the motor, most often caused by the obstacle
appearing on the way of the gate.
2. Introduction
This instruction manual is dedicated to SWIFT6- CB driver. This driver enables to connect safety devices
such as photocells, pressure edges and it also has encoder system efficiently detecting the overloading caused by
the unintentional resistances in the move of the gate. The driver detects and also uses the operation of internal
magnetic limit switches of the motor. Moreover, the driver enables the adjustment of the power and has a
function of slowing down during start and stop. The driver has a radio receiver connector.
3. Technical data
Basic parameters
?
Power supply
230V AC, 50 Hz
?
Operation temperature (min./max.)
-20°C /+55°C
Outputs/Inputs
?
Motor output (voltage/max. power)
230VAC / 1 x 300W
?
Motors power adjustment
electronic with the use of potentiometer
?
Overloading protection
programmed in service mode
?
Signal lamp output
relay (max. 230VAC/5A)
?
Illuminating lamp output
relay (max. 230VAC/5A)
?
Peripheral power supply output (photocells, etc)
24VAC
?
Photocell transmitters power supply output
24VAC (see photo test function)
?
Photocell input/ number
NC/1+1(DIP-SWITCH 3 and 4, tab.1)
?
OPEN mode manual control input
NO
?
CLOSE mode manual control input
NO
?
STOP mode manual control input
NC
?
STEP BY STEP mode manual control input
(open-stop-close-stop)
NO
?
Cooperation with limit switches
yes
?
Opening, closing and
soft start/stop phases time regulation
yes
?
Auto-closing/auto-photo closing time regulation
yes/ 2s
Controlling part
?
Photo test
(photocells testing before move of the gate)
yes
?
Photocells operation mode
stop and continue, move reverse
Radio part
?
Radio card
optional TRX series card
?
Aerial
clamps in motor to connect external aerial
3