4
4. Installation
4.1. Important reminder
CAUTION! Electrical installations and automations of the drive must be made by experienced and
trained staff under effective laws and regulations.
Dangerous voltage 230V 50Hz appear in the devices, all connections should be made at the voltage switched off.
Installer's task is to install the system safely enough to minimize the risk associated with using it. Person who makes
the installation without observing the applicable regulations is responsible for the possible damage which can be
caused by the device.
4.2. Description of particular elements of the driver
Motherboard of the driver (fig. 1) has power supply unit and an implementation circuit made on specialist
transmitters, as well as connectors for connecting supply voltage, motor and protecting, steering and signal
elements. It also has microprocessor control unit. Presence of the supply voltage
is signalled with the LED diode lighting.
CAUTION!
Switchboard settings incorrectly adjusted to installation conditions can soon lead to its damage and
loss of warranty!
After the completion of creating the installation and connecting devices stage, it is
necessary to programme the switchboard in order to adapt its operation parameters to the current
installation, in particular it is necessary to:
4
always set the power of motors
4
always set opening and closing times and the limit of overloading safety barrier
Scrupulously follow designed connections. If uncertain, do not try but read relevant detailed technical
cards of installed devices. Incorrect connections can cause serious damage in the driver and other devices
1.
Connector powering the transformer.
2.
Transformer.
3.
Fuse 0,3A/250V.
4.
Terminal block for connecting the secondary winding of the transformer.
5.
Terminal block for connecting magnetic limit switch.
6.
Programming/gate stopping button PROG/STOP
7.
Step by step function button P/P
8.
Potentiometer of the engine power regulation.
9.
Jumper (for switching off the engine amperometry and soft start).
10.
Radio card connector.
11.
DIP-SWITCH, see tab.1.
12.
FOTO-TEST jumper.
13.
Connector for encoder.
14.
Terminal block for connecting accessories.
15.
RESET pins. Closing these pins for a moment has the same effect as turning off power supply for a
moment
16.
Input status signal diodes (switched on – input closed)
17.
Programming diode (L1)
18.
Connector for electro lock.
19.
Terminal block for signal and illumination lamps 230VAC.
20.
Terminal block for connecting drive power supply 230VAC.
21.
Fuse F6, 3A/250V.
22.
Terminal block for connecting engine and condenser.
STOP BUTTON CAN NOT BE USED AS SAFETY DEVICE, ONLY AS SERVICE FUNCTION TO MAKE
INSTALLATION TESTS EASIER.
Содержание SWIFT6
Страница 2: ......