Страница 2: ...fore installing the opener 4 Where possible install the door opener 7 feet or more above the floor Mount the emergency release 6 feet above the floor 5 Do not connect the opener to the source of power...
Страница 3: ...e cela est possible installer l l ouvre porte 2 14m ou plus au dessus du sol Monter le d verrouillage d urgence 1 83m au dessus du sol 5 Ne pas brancher l ouvre porte la source d alimentation lectriqu...
Страница 4: ...15 3 Install the Control Head Page 5 15 4 Fit the Manual Override Page 6 16 5 Fit the Control Box Page 6 16 6 Fit the optional Automatic Lock Page 7 17 7 Connect to the power supply Page 7 17 8 Insta...
Страница 5: ...ing the operator 5 Fitting the Control Head 6 Fitting the Manual Override Lever 7 Fitting the Control Box 7 8 Fitting the optional Automatic Lock 8 Supply outlet information 8 Accessory wiring 8 Built...
Страница 6: ...pending on the door position A significant advantage of the ZAP drive system with its soft start and its fast obstruction sensing is that when an object obstructs the door s travel the cables will pro...
Страница 7: ...e the other end to the torque arm fixing hole on the Control Head use the supplied spacer if the offset is not enough to clear the drum Pic 5 Pic 5 Align the Control Head driven pulley s keyway with t...
Страница 8: ...ecure the lever using the M5 screws and flange nuts supplied Pic 9 Pic 9 Place the hook in the cable D shackle or a convenient link of the chain and ensure that the lever is slightly above horizontal...
Страница 9: ...d Pic 15 Pic 15 SUPPLY OUTLET A 115V 60Hz grounding type outlet is required for the 8825 R4 this should be installed by a qualified electrician in accordance with the local electrical codes within 4 o...
Страница 10: ...AFETY and Pic 19 Note The supplied photo eyes are not polarity sensitive and can be wired either way around Pic 19 When the photo eyes are properly aligned the red safety light on the Control Box circ...
Страница 11: ...rd stage to end 4 Once the third stage of the calibration process is complete the door will be closed and the Operator Light will be lit with the beeper sounding once every 5 seconds to indicate entry...
Страница 12: ...obstruction A calibration reset pages 9 10 is required for a new setting to take effect Release the PROGRAM button after the fourth beep to program the closing speed change point 14 beeps representing...
Страница 13: ...ILLUMINATED button after the first beep for vacation mode The light goes out and the radios and external inputs are all ignored until the button has been pressed again to leave vacation mode Release t...
Страница 14: ...omatically opens REASON REMEDY A The V belt tension is too loose and the belt is slipping over the motor pulley Increase the tension by releasing the Manual Override Lever and screwing the hook in a f...
Страница 15: ...e ZAP Controller has not been calibrated to this door Refer to the calibration process on pages 9 and 10 C The obstruction tolerance may be too low Refer to the Installer Programming instructions on p...