Specification
Page 19 of 188
057-254 ISSUE: 2
2.7.3 ANALOGUE INPUTS
All of the analogue inputs are flexible within the DSE8610 MKII module
2.7.3.1
ANALOGUE INPUT A
Description
Specification
Input Type
Flexible: Configured for Oil Sensor in the DSE default configuration.
Flexible Options: Not used, Digital Input, Flexible Analogue Oil
Sensor
Flexible Input Selection
Pressure Sensor, Percentage Sensor or Temperature Sensor
Flexible Measured Quantity
Current, Restive or Voltage
Resistive Configuration
Description
Specification
Measurement Type
Resistance measurement by measuring voltage across sensor with
a fixed current applied
Arrangement
Differential resistance measurement input
Measurement Current
15 mA ± 2 mA %
Full Scale
480
Ω
Over Range / Fail
600
Ω
Resolution
±1 % of full scale
Accuracy
±2 % of full scale resistance (±9.6
Ω
) excluding sensor error
Max Common Mode Voltage
±2 V
Display Range
0 % to 250 %, 0
°
C to 250
°
C (32 °F to 482 °F) or 0 bar to 17.2 bar
(0 PSI to 250 PSI) subject to limits of the sensor and sensor
configuration
0 V to 10 V Configuration
Description
Specification
Full Scale
0 V to 10 V
Over Range / Fail
11 V
Resolution
±1% of full scale
Accuracy
±2% of full scale voltage (±0.2 V) excluding sensor error
Max Common Mode Voltage
±2 V
Display Range
0 % to 250 %, 0
°
C to 250
°
C (32 °F to 482 °F) or 0 bar to 17.2 bar
(0 PSI to 250 PSI) subject to limits of the sensor and sensor
configuration
4 mA to 20 mA Configuration
Description
Specification
Full Scale
0 mA to 20 mA
Over Range / Fail
22 mA
Resolution
1% of full scale
Accuracy
±2% of full scale current (±0.4 mA) excluding sensor error
Max Common Mode Voltage
±2 V
Display Range
0 % to 250 %, 0
°
C to 250
°
C (32 °F to 482 °F) or 0 bar to 17.2 bar
(0 PSI to 250 PSI) subject to limits of the sensor and sensor
configuration
Содержание 8610 MKII
Страница 63: ...Installation Page 63 of 188 057 254 ISSUE 2 3 4 2 SINGLE PHASE L1 N 2 WIRE WITHOUT EARTH FAULT...
Страница 65: ...Installation Page 65 of 188 057 254 ISSUE 2 3 4 4 SINGLE PHASE L1 L2 3 WIRE WITHOUT EARTH FAULT...
Страница 67: ...Installation Page 67 of 188 057 254 ISSUE 2 3 4 6 SINGLE PHASE L1 L3 3 WIRE WITHOUT EARTH FAULT...
Страница 69: ...Installation Page 69 of 188 057 254 ISSUE 2 3 4 8 2 PHASE L1 L2 3 WIRE WITHOUT EARTH FAULT...
Страница 71: ...Installation Page 71 of 188 057 254 ISSUE 2 3 4 10 2 PHASE L1 L3 3 WIRE WITHOUT EARTH FAULT...
Страница 72: ...Installation 057 254 ISSUE 2 Page 72 of 188 3 4 11 3 PHASE 3 WIRE DETLA WITHOUT EARTH FAULT...
Страница 82: ...Installation 057 254 ISSUE 2 Page 82 of 188 3 5 7 SINGLE GENERATOR EXPORTING BASE LOADING POWER...
Страница 187: ...This Page is Intentionally Blank...
Страница 188: ...This Page is Intentionally Blank...