30
[07]
Third System Options
1 Entry Delay Off Arming Option
ON:
“No Entry Delay” Option Available.
When arming the system in the Home Mode, the
user will be able to select whether or not Delay Zones will have an entry delay when
opened.
•
OFF:
“No Entry Delay” Option Not Available.
Delay Zones will always have an entry delay.
2 Silent Supervisory Fault
ON:
Supervisory Faults are Troubles Only.
When a Supervisory Fault occurs, a trouble
beep will sound if the system is armed or disarmed and the appropriate reporting code
will be transmitted to the monitoring station.
OFF:
Silent Supervisory Fault Disabled.
When a Supervisory Fault occurs, a trouble beep
will sound if the system is disarmed. When the system is armed, the system will sound
an alarm condition on the sounder(s). In both instances, the appropriate reporting code
will be transmitted to the monitoring station.
3 Tamper Faults Transmit Only while Armed
ON:
Tamper Faults Transmit Only while Armed Enabled.
Tamper faults generated only
while the system is armed will be reported. If a tamper fault occurs while the system is
disarmed, the Sounders will sound a trouble indication, but the fault will not be reported.
•
OFF:
Tamper Faults Transmit Only while Armed Disabled.
Tamper faults will always be
transmitted, regardless of whether the system is armed or disarmed.
24-Hour Zones must be bypassed to avoid alarms while changing batteries.
4 Interior Zone with Delay
ON:
Interior Zone with Delay Enabled.
When the system is armed in the “Away” mode,
zones programmed as “Interior” will operate in the same manner as Delay 1 zones.
However, the Interior zones will be bypassed when the system is armed in the “Home”
mode.
•
OFF:
Interior Zone with Delay Disabled.
When the system is armed in the “Away” mode,
zones programmed as “Interior” will generate an immediate alarm if activated. However,
the Interior zones will be bypassed when the system is armed in the “Home” mode.
5 Exit Delay Termination
ON:
Exit Delay Termination Enabled.
The Exit Delay will be terminated when the Entry/Exit
Delay Zone is opened and closed during the Exit Delay. All audible options associated
with the Delay will be silenced, and the system will be armed.
•
OFF:
Exit Delay Termination Disabled.
The Exit Delay timer will continue for the entire Exit
Delay, regardless of any zone activity during the Exit Delay. All audible options
associated with the Exit Delay will function until the Exit Delay expires.
6 Audible Home Mode Arming
ON:
Audible Home Mode Arming Enabled.
When the system is armed in the Home Mode,
the Exit Delay will be audible.
•
OFF:
Audible Home Mode Arming Disabled.
When the system is armed in Home Mode, the
Exit Delay will be silent.
7 - 8
For Future Use
•
Indicates default setting
Chapter 8: System Programming Sections