Appendix A: Reporting Code Formats
Appendix A: Reporting Code Formats
The following tables contain Contact ID and Automatic SIA format reporting codes. See Programming Sections [320]-[348] for Report-
ing Codes.
&RQWDFW,'
The first digit (in parentheses) is automatically sent by the control. The second two digits are programmed to indicate specific informa-
tion about the signal. For example, if zone 1 is an entry/exit point, you could program the event code as [34]. The central station would
receive the following:
*BURG - ENTRY/EXIT - 1 where the “1” indicates which zone went into alarm.
6,$)RUPDW/HYHO+DUG&RGHG
The SIA communication format used in this product follows the level 2 specifications of the SIA Digital Communication Standard-
October 1997. This format will send the Account Code along with its data transmission. The transmission will look similar to the fol-
lowing at the receiver:
Note:
A system event will use the Area Identifier ri00.
N ri1= BA 01
N = New Event
ri1 = Partition /Area Identifier
BA= Burglary Alarm
01= Zone 1
Table 1: Reporting Codes
6HFWLRQ
5HSRUWLQJ&RGH
&RGH6HQW:KHQ
'LDOHU
'LUHFWLRQ
$XWRPDWLF
&RQWDFW,'
&RGHV
6,$$XWR
5HS&RGHV
[320]
Zone Alarms
Zone goes into alarm
A/R
See the tables on next
page for details
[324]
Zone Restores
Alarm condition has been restored
A/R
[328]
Duress Alarm
Duress code entered at keypad
A/R
E(1)21-000 HA-00
[328]
Opening After Alarm
System disarmed with alarm in memory
A/R
E(4) 58-UUU
OR-UU
[328]
Recent Closing
Alarm occurs within two minutes of system arming
A/R
E(4)59-
UUU
CR-UU
[328]
Zone Expander Supervi-
sory Alarm/Rest.
Panel loses/restores supervisory transmission over the
Keybus from zone expansion modules or keypads with
zone inputs
A/R
E(1)43-000/
R(1) 43-000
UA-00/
UH-00
[328]
Cross Zone (Police Code)
Alarm
Two zones on the same partition go into alarm during any
given armed-to-armed period (incl. 24Hr zones)
A/R
E(1)39-000 BM-00/BV-00
[328]
Alarm Cancelled
Sent when the system is disarmed after an alarm, but
before the expiry of the alarm cancellation timer.
A/R
E(4)A6-UUU OC-UU
[329]
[F] Key Alarm/Rest.
Keypad fire alarm (alarm and restore rep. codes sent
together)
A/R
E(1)1A-000/
R(1)1A-000/
FA-00/FH-00
[329]
[A] Key Alarm/Rest.
Keypad auxiliary alarm (alarm and restore rep. codes sent
together)
A/R
E(1)AA-000/
R(1)AA-000/
MA-00/MH-00
[329]
[P] Key Alarm/Rest.
Keypad panic alarm (alarm and restore rep. codes sent
together)
A/R
E(1)2A-000/
R(1)2A-000
PA-00/PH-00
[329]
Auxiliary Input Alarm/Rest. Option#23-24: a panic button wired to PGM 2 is pressed/
access code is entered.
Option #04: a 2-wire smoke detector wired to PGM 2 goes
into alarm/alarm is cleared.
A/R
E(1)4A-000/
R(1)4A-000
E(1)11-000/
R(1)11-000
UA-99/UH-99
FA-99/FH-99
[330], [334] Zone Tamper/Restore
Zone is tampered / tamper condition restored
T/R
E(3)83-ZZZ/
R(3)83-ZZZ/
TA-ZZ/TR-ZZ
[338]
General System Tamper/
Rest.
Case/cover has a tamper alarm. Case/cover tamper
restored
T/R
E(1)45-000/
R(1)45-000
ES-00/EJ-00
[338]
Keypad Lockout
Maximum number of incorrect access codes has been
entered at a keypad
T/R
E(4)61-000 JA-00
[339-341],
[601]
Closings
System armed (user 01-39, 40 indicated)
O/C
R(4)A1-UUU
CL-UU
[341]
Automatic Zone Bypass
A zone was bypassed at the time of arming
O/C
E(5)7A-ZZZ UB-ZZ
[341]
Partial Closing
One or more zones bypassed when system armed
O/C
E(4)56-000 CG-00
[341]
Special Closing
Closing (arming) using one of the following methods: quick
arm, keyswitch, function key, maintenance code, DLS
software
O/C
R(4)AA-000 CL-00
[341]
Late to Close
Whenever the Auto-arm pre-alert sounds (if the Late to
Close option is enabled)
O/C
R(4)54-000 CI-00
[341]
Exit Fault
Sent when an exit error occurs and the Entry Delay
expires before the system is disarmed
O/C
E(3)74-ZZZ EA-ZZ
[342-344],
[605]
Openings
System disarmed (user 01-39, 40 indicated)
O/C
E(4)A1-UUU
OP-UU
[344]
Special Opening
Opening (disarming) using one of the following methods:
keyswitch, maintenance code, DLS software
O/C
E(4)AA-000 OP-00
[345]-[346] Battery Trouble/Rest.
PC1404 System battery is low/battery restored.
MA/R
E(3)A2-000/
R(3)A2-000
YT-00/YR-00