5 Programming Worksheets
19
5.2 Programming Worksheets
Keypad Partition/Slot and Function Key Programming
[000] Function Key Programming
Note:
Keypad enrollment must be done at each keypad requiring programming. Function keys are programmable in each individual
keypad. The keypad being programmed must be used to access Installer Programming, followed by Section [000] and digits 1-5 for
function keys 1 to 5.
Function Key Options
[001] Zone Definitions
[001]
Zone 1–8 Definitions
[0] Slot address
For the partition, 0-8; for the slot, 1-8. For example, to enroll a keypad on the main partition and slot 6,
enter 16.
[1] Function Key 1 Assignment Valid entries are 00-25
[2] Function Key 2 Assignment Valid entries are 00-25
[3] Function Key 3 Assignment Valid entries are 00-25
[4] Function Key 4 Assignment Valid entries are 00-25
[5] Function Key 5 Assignment Valid entries are 00-25
00
Null Key
09
Future Use
18
Future Use
01
Future Use
10
Future Use
19
[
,
][7][3] Command Output #3
02
Future Use
11
Future Use
20
Night Arm
03
Stay Arm
12
Future Use
21
[
,
][7][4] Command Output #4
04
Away Arm
13
[
,
][7][1] Command Output #1
22
Future Use
05
[
,
][9] No Entry Arm
14
[
,
][7][2] Command Output #2/Sensor Reset
23
Future Use
06
[
,
][4] Chime On / Off
15
Future Use
24
Future Use
07
Future Use
16
[
,
][0] Quick Exit
25
Instant Stay Arm
*
08
[
,
][1] Bypass Mode
17
[
,
][1] Reactivate Stay/Away Zones
26-33
Future Use
*
This function
key must not be used in CP-01 listed systems.
Key 1
Key 2
Key 3
Key 4
Key 5
Keypad Defaults
BBB
BBB
BBB
BBB
BBB
00
Null Zone (Not Used)
14
24 Hour Heat*
28
Not Used
01
Delay 1*
15
24 Hour Medical*
29
Auto-verified fire
02
Delay 2*
16
24 Hour Panic*
30
Not Used
03
Instant*
17
24 Hour Emergency*
31
Day Zone
04
Interior*
18
Not Used
32
Instant Stay/Away*
05
Interior, Stay/Away*
19
24 Hour Water*
33
Not Used
06
Delay, Stay/Away*
20
24 Hour Freeze*
34
Not Used
07
Delayed 24 Hr. Fire
21
24 Hour Latching Tamper
35
24 Hour Bell
08
Standard 24 Hr. Fire
22
Momentary Keyswitch Arm*
36
24 Hr. Non-Latching Tamper
09
24 Hour Supervisory
23
Maintained Keyswitch Arm *
37
Night Zone*
10
24 Hour Supervisory Buzzer*
24
Not Used
41
24-Hour CO Detection
11
24 Hour Burglary*
25
Interior Delay*
12
Not Used
26
24-hour Non-Alarm (Local Alarm)
13
24 Hour Gas*
27
Not Used
*For burglary applications only
Note:
Don’t enable cross zoning on fire zones or auto-verified fire zones (zone type 29).
Zone
Default
Zone
Default
01
01
I_____I_____I
05 (ZD or keypad zone only)
04
I_____I_____I
02
03
I_____I_____I
06 (ZD or keypad zone only)
04
I_____I_____I
03
03
I_____I_____I
07 (ZD or keypad zone only)
04
I_____I_____I
04
03
I_____I_____I
08 (ZD or keypad zone only)
04
I_____I_____I
Note:
If zone doubling is enabled, keypad zones will not work.
Note:
If zone doubling is enabled, fire zones cannot be used with zone terminals 1 to 8. Two-
wire smoke detectors can still be used.