PC1404
8
2.14 PC1404RKZ Installation Instructions
The PC1404RKZ is compatible with the PC1404 security sys-
tem. These instructions shall be used in conjunction with the
Installation Manual of the PC1404 alarm controller.
The PC1404RKZ keypad presents system status using LEDs
along with symbols and numbers. The keypad can be used on
security systems with up to 8 zones.
Specifications
•
Supply voltage: 7VDC-14.5VDC
•
Compatible control panel keybus connection provided by
DSC
•
Connects to control panel via 4-wire keybus
•
One keypad zone input
•
Current draw: 120mA (maximum)
•
Optional tamper version
•
Four programmable function keys
•
Ready (green), Armed (red), and Trouble (amber) status
lights
Note:
This keypad is available to order with white (WH) or
yellow (YEL) LED backlights.
Unpacking
The PC1404RKZ package includes the following parts:
•one PC1404RKZ keypad •one tamper switch
• three mounting screws
•one set of Installation Instructions
• three anchors for
•keypad inner door labels
wall-mounting screws
• one end-of-line resistor
Mounting
Mount the keypad where it is accessible to designated points of
entry and exit. Once a dry and secure location is selected, per-
form the following steps to mount the keypad:
1.
Remove the keypad frontplate by inserting a screwdriver
into the slots located on the top of the keypad.
2.
Secure the keypad backplate to the wall in the desired loca-
tion. Use all the screws provided. Use the plastic anchors
supplied if the unit is to be mounted on drywall.
3.
To use the keypad tamper, insert the supplied tamper
switch into the opening located in the centre of the back-
plate, and secure the tamper to the wall with a screw.
4.
For tamper use, the backplate should be mounted on a
smooth, flat surface. If mounting on a rough surface, fasten
the enclosed surface tape to the wall to even out the surface
area where the tamper will be positioned.
5.
Before attaching the keypad to its backplate, complete the
keypad wiring as described in the next section.
Wiring
1.
Before wiring the unit, ensure that all power (AC trans-
former and battery) is disconnected from the control panel.
2.
Connect the four Keybus wires from the control panel (red,
black, yellow and green) to the keypad terminals (RED,
BLK, YEL, GRN). Consult the diagram below:
3.
Connect a device, such as a door con-
tact, to the ‘Z’ terminal of the
PC1404RKZ. This eliminates the
need to run wires back to the control
panel for the device. To connect the
zone, run one wire from the device to
the ‘Z’ terminal and the other wire
from the device to the BLK (black) terminal. For powered
devices, run the red wire to the RED (positive) terminal and
the black wire to the BLK (negative) terminal. When using
end of line supervision, connect the zone according to one
of the configurations outlined in your system’s Installation
Manual.
Applying Power
Once all wiring is complete, apply power to the control panel:
1.
Connect the battery leads to the battery.
2.
Connect the AC transformer.
For more information on control panel power specifications, see
the control panel Installation Manual.
Note:
Do not connect the power until all wiring is complete.
Enrolling the Keypad
See 2.6 Keypad Assignment to enroll the keypad.
Power Save Mode
If power save mode is enabled and AC power fails, all keypad
lights, including backlighting, shut off. The keypad lights will
come back ON after a keypress, entry delay, audible alarm or
keypad buzzer condition (except door chime). The keypad lights
will return to the off state after 30 seconds of no activity. If the
AC fail condition is restored, the keypad lights will be
reactivated.
Keypad Icons
Changing the Buzzer Level
The user can change the keypad buzzer frequency by pressing
and holding the [*] key. After the key has been pressed for 2 sec-
onds, the keypad changes the frequency and beeps so the user
1
4
7
*
2
5
8
0
3
6
9
#
Ready Status
The green ready status icon is on when the system is
ready to arm.
Armed Status
The red armed status icon is on when the system has
been successfully armed.
Trouble
Status
The trouble status icon is lit when there is a trouble
present on the system. To see if a trouble is present
press [*][2]. If any number is lit, a trouble condition is
present. Refer to your system manual to identify what
trouble condition is present.
AC Status
The green AC status icon can be configured to indicate
presence or absence of AC; see AC LED Options and
Keypad Toggle Options sections [5] and [6].
Fire Memory
The red fire memory icon is lit when a fire alarm is in
progress or has occurred. If zone 4, as an example, is
programmed as a fire zone and goes into alarm, the
keypad will turn on the zone 4 LED and the fire icon to
indicate a fire alarm is present on zone 4.
Alarm
Memory
The alarm memory icon is lit when there is a zone in
alarm memory. To see if there is a zone in alarm
memory press [*][3]. If any number is lit, the
corresponding zone is in alarm memory. Refer to your
system manual for further information.
Bypass
The bypass icon is lit when a zone is bypassed on the
system. To see if a zone is bypassed press [*][1]. If any
number is lit, the corresponding zone is bypassed. Refer
to your system manual for information on bypassing and
removing a bypass.
Programming
The programming icon indicates when the keypad is in
Installer Programming. This LED also activates when
the keypad is busy.
To Zone Input
GRN
YEL
BLK
PC1404RKZ
RED
GRN Z
YEL
BLK
RED