format
reporting
Requires:
l
account code in sections
or
For example, enter 1230 for account code 123
l
Format Code [0],
depending on receiver type in section
l
Single line
Alarm Reporting Code Section
For example, enter
for
single digit code 3 (0 = no pulses)
TRANSMISSION SENT: 123 3
Format Non-extended reporting
Requires:
l
4-digit account code in sections
or
For example, enter 1230 for account code 123
l
Format Code [0],
depending on receiver type in section
l
Alarm Reporting Code in section
For example, enter
for 2-digit code 31
TRANSMISSION SENT: 1234 31
Format Extended reporting
Requires:
l
Account Code in section
or
For example, enter 1230 for code 123
Format Code
[A],
[C] depending on receiver type in section
l
Alarm Reporting Code in section
For example, enter
for 2-digit code 31
TRANSMISSION SENT: 1
st ROUND
123 3
2nd ROUND 333 1
If a transmission is not needed for a particular reporting code, enter [00] or [FF] to disable that reporting code.
Zone
Reporting Codes
Zone
Codes are transmitted when zones 1 through 6 are restored from an alarm condition. Refer to
Section
for programming instructions.
(Arming) Reporting Codes Partial
Reporting Code
Closing Reporting Codes are transmitted to
identify
arming
of the system
by
Access Codes 1 through 6. If Partial
Closing is identified in Section
the alarm codes for manually bypassed zones will be transmitted when the
system is armed with one or more zones bypassed. Refer to Section
for programming instructions. The
Closing Reporting Codes may be programmed as follows:
The first digit, HEX ‘C’, represents “closing”, and the second digit represents the Access Code which was used
to arm the system. Note that any number or HEX digit may be used for the first digit; check with the intended
monitoring station to determine their reporting code preferences.
The Closing Code transmission takes place
after
the Exit Delay. If the system is
armed
and then disarmed before
the Exit Delay expires, no closing transmission will take place.
The partial closing code, if used, is transmitted with the regular closing code to identify a partial closing.
When the system has been armed using the
Quick-Arm command or the Auto-Arm feature,
Access Code 1 will be transmitted.
15