53
When performing the
module placement test
, the
unit must be tampered by removing the unit from the
backplate and replacing it. The placement test cannot be
performed by creating motion in front of the device.
When performing a
walk test
, the unit must be left
idle for three minutes before testing can be performed.
Once three minutes has passed, create motion in front
of the detector to see if the device is both detecting
motion and transmitting to the receiver.
Motion Detector Transmission Delay
A motion detector transmission is always delayed by six
seconds. This is necessary to prevent false alarms caused
by a motion sensor transmitting before a delay zone has
a chance to report. This six-second delay cannot be
altered or disabled.
Walk Test Mode
The motion detector has a walk test mode which will
activate an LED for testing purposes. During normal oper-
ation, the LED will not turn on.
To put the detector in walk test mode, create a tamper by
removing the detector from its backplate and then
replacing it. Each time the detector senses motion, it will
turn on the red LED. Five seconds after motion is
detected, the detector will send a signal to the receiver,
and the LED will flash rapidly 5 times. The detector will be
in walk test mode until it has sent 10 transmissions.
To verify the pet immunity of the detector place the ani-
mal(s) within the coverage area and then move out of the
zone. Encourage the pet to move around as it normally
would and ensure that it moves across the detection pat-
tern of the detector. Verify that no alarm is initiated. To
test for catch performance of humans, create motion in
the entire area where coverage is desired by walking per-
pendicular to the lens pattern. Should the coverage be
incomplete, readjust or relocate the detector.
☞
The Walk Test Mode will override the High
Traffic Shutdown Mode.
Battery Installation
• This system is designed to work with the Energizer
Lithium EL123AP, Tekcell CR123A Lithium or Pana-
sonic Lithium CR123A battery. Do not install any
other type. The reliability of the security system
depends on its batteries.
• Use fresh batteries. Buy batteries that have a “best
before” date of two years or more from your pur-
chase date.When disposing of used batteries, fol-
low the instructions and precautions printed on
the battery. Many cities and communities have col-
lection sites or services for used household batter-
ies. Contact your municipal offices for information
on the disposal of used batteries.
Remove the motion detector from its mounting plate
by holding the sensor by its sides and pushing up.
Remove the battery cover, then remove the old bat-
tery and wait at least 90 seconds. Install new battery.
Place the battery cover back on. Secure the battery
cover with the small screw provided. Replace the sen-
sor on its mounting plate, making sure it snaps into
place. After the battery is installed, the detector will
take 60 seconds to warm up. During this time the LED
will flash slowly.
☞
NOTE: The polarity of the batteries must be
observed. Improper handling of lithium batter-
ies may result in heat generation, explosion or
fire, which may lead to personal injuries.
Keep away from small children. If batteries are swal-
lowed, promptly see a doctor. Do not try to recharge
these batteries. Disposal of used batteries must be
made in accordance with the waste recovery and recy-
cling regulations in your area.
☞
Please refer to the WLS904PL-433 Installation
Instructions for more information.
TOP VIEW
SIDE VIEW
Detection Pattern
"Fast" Setting - 40ft x 40ft
"Slow" Setting - 35ft x 35ft
firealarmresources.com