Advanced Programming
40
6
ON
Alternate Dial (1st & 3rd)
After each dialing attempt, the communicator switches
between the 1st phone number and 3rd phone number until
all attempts have been made to each number.
OFF Call 1st Number, Backup to 3rd Number
✓
If attempts to communicate to the first telephone number
fail, the system will attempt to communicate to the third tele-
phone number. If all attempts (see
section [160]
) to commu-
nicate to the third telephone number fail, a Failure to
Communicate (FTC) trouble will be generated.
7
ON
Partial Closing I.D. is 5 (Contact I.D.)
The event code associated with this is identified as a Open/
Closing event to the central station.
OFF Partial Closing I.D. is 4 (Contact I.D.)
✓
The event code associated with this is identified as a Disable/
Bypass event to the central station.
8
ON
Activity Delinquency
This feature assists in the monitoring of the elderly and the
handicapped. If there is no zone activity on the system, the
Delinquency Transmission Delay timer in
section [370]
option [10]
will begin counting in hours. When the counter
reaches the programmed time, the panel will communicate
the Delinquency Code to the central station, if programmed.
If there is zone activity present on the system at any time, the
counter will be reset. If this option is used, the Closing Delin-
quency option is not available.
☞
This code will not be transmitted for panels that are Away
armed. Activity on bypassed zones does not affect this timer.
This timer is also reset upon arming.
OFF Closing Delinquency
✓
This reporting code is sent whenever the programmed num-
ber of days for Delinquency has expired without the panel
being armed. The timer for this feature is programmed in
section [370]
. The value programmed in this section deter-
mines the number of days the panel counts when not being
armed before sending the Delinquency reporting code to the
central station. Once this code is sent, the timer will not be
started again until the panel has been armed. Each day pro-
grammed in the counter represents one day PLUS the time it
takes for the panel to reach midnight. This feature may be
disabled by programming
[000]
in
section [370]
.
[381] Second Communicator Option Code
1
ON
Opening after Alarm Keypad Ringback
Enabled
When the
Opening after Alarm
reporting code is transmit-
ted to a programmed telephone number, the keypad will
sound 8 beeps to confirm that the
Opening After Alarm
Code
was sent and received. This ringback will occur for each
Opening After Alarm code successfully reported.
OFF Opening after Alarm Keypad Ringback Dis-
abled
✓
2
ON
Opening after Alarm Bell Ringback
Enabled
When the Opening After Alarm reporting code is transmitted
to a programmed telephone number, the bell will sound 8
squawks to confirm to the end user that the
Opening After
Alarm Code
was sent and received. This ringback will occur
for each
Opening After Alarm
code transmitted.
OFF Opening after Alarm Bell Ringback Dis-
abled
✓
3
ON
SIA Sends Programmed Report Codes
The codes programmed in
sections [320]-[353]
will be sent
in accordance with the call directions programmed in
sec-
tions [361]-[367]
, if it has been enabled in
section [360]
. If
‘FF’
or
‘00’
is entered into the associated section, no code will
be transmitted. The codes will be sent in the SIA format.
OFF SIA Sends Automatic Report Codes
✓
Pre-programmed SIA reporting codes (See App. A) will be
sent in accordance with the call directions programmed in
sections [361]-[367]
, if it has been enabled in
section [360]
and if
‘01-FF’
is entered in the associated progamming sec-
tion (
[320-353]
). If
‘00’
has been entered into the associated
section, no code will be transmitted.
4
ON
Closing Confirmation Enabled
When a Closing reporting code is successfully transmitted to
a programmed telephone number, the keypad will sound a
series of 8 beeps to confirm to the end user that the Closing
Code was sent and received.
OFF Closing Confirmation Disabled
✓
There will be no keypad ringback when a Closing reporting
code is successfully transmitted to a programmed telephone
number.
5-6
Future Use
7
ON
Contact I.D. Uses Programmed Report
Codes
The codes programmed in
sections [320]-[353
] will be sent
in accordance with the call directions programmed in
sec-
tions [361]-[367]
, if it has been enabled in
section [360]
. If
‘FF’
or
‘00’
is entered into the associated section, no code will
be transmitted. The programmed codes will be sent in the
ADEMCO protocol.
OFF Contact I.D. Uses Auto-reporting Codes
✓
Pre-programmed Contact I.D. reporting codes (See App. A)
will be sent in accordance with the call directions pro-
grammed in
sections [361]-[367]
, if it has been enabled in
section [360]
and if
‘01-FF’
is entered in the associated prog-
amming section (
[320-353]
). If
‘00’
has been entered into the
associated section, no code will be transmitted.
8
Future Use
firealarmresources.com
Содержание Envoy NT9005EU
Страница 58: ...NOTES firealarmresources com ...