5.3.4 Calibrate Sensor
–
Enhanced Method
–
Online Sample value display
If no value is displayed for the “Online Sample” No calibration is in
progress. Or the 30 second sample period has not yet elapsed. Or
you have been returned to this screen after completing a
calibration entry.
Press
the “
Touch area
”
<
Manual Sample>
to display the Sample
entry screen
Press the “
Touch area
”
<Cancel>
to cancel a calibration in
progress.
Press the “
Touch area
”
<Exit>
to return to the main screen
Press the “
Touch area
”
<Back>
to return to the previous screen
Figure 37.
–
Calibrate Sensor (Enhanced method) Sample Display
5.3.5 Calibrate Sensor
–
Enhanced Method
–
Sample entry
Press the “
Touch area
”
<keypad>
to enter the manual test value.
Press the “
Touch area
”
<Enter>
to accept the value and return to
the previous screen.
Or
press the “
Touch area
”
<Esc>
to cancel and return to the
previous screen.
Figure 38.
–
Calibrate Sensor (Enhanced method) Sample Entry
How calibration works:
The purpose of calibration is to allow the Dryer Master moisture reading to easily mimic the manual
tester. Periodic checks against a manual device ensure both are in approximate agreement. Please be
sure the product moisture and product temperature are within the specification range for your manual
tester. Many of the grain moisture testers have specific moisture and temperature ranges. Testing
product outside of these ranges can severely impact the device accuracy. The Dryer Master Moisture
sensor is able to measure moisture from well below freezing to just below the boiling point of water.
Therefore the Dryer Master sensor may well give you a correct moisture reading but your manual
tester can not.
1)
Standard method:
The standard calibration method transfers you to a screen which displays the current moisture.
While on this screen you will press the “
+
” or “
-
” “
Touch keys
” to adjust the displayed reading to
best mimic the manual test you took previously. Please note there is may be some time
difference between the sample you tested and the currently displayed moisture. Care must be
taken when adjusting the displayed moisture reading to ensure it is corrected for the moisture
at the time the sample was taken.
SYSTEM
F1
F2
F3
F4
Exit
Cancel
Calibration
Online Sample
Manual Sample
Back
14.6%
0.0%
14.00
_QZ
1
GHI
4
PRS
7
TUV
8
WXY
9
.
SYSTEM
F1
F2
F3
F4
0
+/-
ABC
2
DEF
3
JKL
5
MNO
6
Enter
Esc
Содержание AM3
Страница 1: ......
Страница 84: ...Dryer Master AM3 Product Manual Dryer Master Inc Page 82 11 Appendix C IMO Set up Guide ...
Страница 85: ...Dryer Master AM3 Product Manual Dryer Master Inc Page 83 ...
Страница 86: ...Dryer Master AM3 Product Manual Dryer Master Inc Page 84 ...
Страница 87: ...Dryer Master AM3 Product Manual Dryer Master Inc Page 85 ...
Страница 88: ...Dryer Master AM3 Product Manual Dryer Master Inc Page 86 ...