background image

Page 2

 

 

sale[email protected]

 

www.drucegrove.com

 

Tel: +44 (0) 1992 650486     Fax: +44 (0) 01992 652226 

 

Drucegrove Ltd

,

 

6 Printers Way, Harlow, Essex, CM20 2SD, UK

 

 

LCD Display Overview

 

F

 

l

 

o

 

o

 

r

 - 

0

 

1

 

h

 

 

 

G

    

 

 

 

 

C

 - 

 

 

L

 - 

 

N

 

e

 

x

 

t

 - 

0

 

2

 

h

  

1

             

A

 - 

 

 

3

 

C

 

O

        

T

 

2

 

1

 

0

 

F

 

F

 

F

 

 

 

B

 

i

 

n

 

.

 

.

 

.

 

.

 

.

 

k

 

.

 

.

 

.

 

.

 

.

 

.

 

d

 

c

 

.

 

.

 

 

 

1

 

 

2

 

$

 

Current Floor 

Designation

 

 

may be up to 4 

characters

 

C#

 

Car Direction

 

Arrow Status

(1)

 

where # may be 

, or 

 for 

no direction

 

L#

 

Hall Lantern

 

Arrow Status

(2)

 

where # may be 

, or 

 for 

no direction

 

Notes

 

(1)

 

Car direction arrows may be set to scroll on

 

indicators by setting dipswitch 8 to ON.

 

(2)

 

Gongs will sound a single tone for 

, a double

 

tone for 

, and will not sound for 

.

 

Next

-

## $

 

Next Stop

 

Floor Address and

 

Floor Designation

 

(only shown if enabled)

 

Floor Input Type

 

(i.e., how the 

F

’ 

inputs are handled)

 

Bin

 

Binary Code

 

Dis

 

Discrete

 

(wire per floor)

 

Gra 

Gray Code

 

Tst 

Test mode

 

(dipswitch 5 on)

 

2

 

Input Board Count

 

 

1 = Single IND055

 

-

 4 = IND055 with Expansion(s)

 

a

 

to

 

p

 

Represents the current active 

state of inputs 1

-

16

 

on the current input board

 

 

‘ 

.

 ’ 

when input is not active

 

a

’ 

through 

p

’ 

when input is active

 

(‘

a

’ 

for input 1, 

b

’ 

for input 2, etc) 

 

1

 

Current Input Board

 

Value indicating which input board

input states are currently being 

shown on the LCD display

 

 

1 = Main IND055 (with LCD display)

 

-

 4 = Expansion Board

 

REFER TO

 

PAGE 8

 

Normal Mode

” 

State (Default when unit is powered up )

 

A#

 

Advanced Hall Lantern

 

Arrow Status

 

(only shown if enabled)

 

where # may be 

,

 

or 

 for no direction

 

Floor

-

##h

 

Current Floor Position Address

 

where ## is a hexadecimal value

 

 

Generally the bottom floor is 01h

 

00h represents no or invalid floor data

 

REFER TO

 

PAGE 6

 

Shows what each of the 16 inputs are configured to represent.

 

i.e., the right most character represents the type of input 1, and the left 

most character the type of input 16.

 

 

No Assignment

 

(input is not used)

 

F

 

Current Floor Position input

 

(right most is LSB/lowest floor)

 

N

 

Next Stop Floor Position input

 

(if next stop inputs are enabled, right most is LSB/lowest floor)

 

0

 to 

9

 

Scrolling Message input

 

(lower number takes priority)

 

 

Hall Lantern Direction down & up inputs

 

 

Car Direction down & up inputs

 

 

Advanced Hall Lantern Direction down & up inputs

 

(if advanced hall lantern inputs are enabled)

 

C

 

(Front) Doors Closing input

 

(if door messages are enabled)

 

O

 

(Front) Doors Opening input

 

(if door messages are enabled)

 

R

 

Rear Doors Closing input

 

(if door messages are enabled)

 

Q

 

Rear Doors Opening input

 

(if door messages are enabled)

 

X

 

Destination Control Hall Call input

 

(discrete floor signals, if destination inputs are enabled)

 

T

 

Speech Trigger for floors

 

(if speech is enabled)

 

D

 

Speech Trigger for door messages

 

(if trigger is enabled)

 

H

 

Hush input for speech and gongs

 

Содержание IND055

Страница 1: ...2 Wire Controller User Manual Issue 16 IND055102 onwards CONTENTS LCD Display Overview 2 Basic Navigation 3 IND055 Controller Functionality 4 IND055 Controller Diagram 4 Sample 2 Wire Installation Dia...

Страница 2: ...Expansion Board REFER TO PAGE 8 Normal Mode State Default when unit is powered up A Advanced Hall Lantern Arrow Status only shown if enabled where may be or for no direction Floor h Current Floor Pos...

Страница 3: ...ther once to enter the floor programming menu Press together a second time to enter the message programming menu Press together a third time to enter the system configuration menu Press together a fou...

Страница 4: ...s and announcements for the car hall lanterns can be reconfigured on site from the IND055 configuration menu independently or together The floor input coding can be easily converted between any of the...

Страница 5: ...GROVE 2 WIRE EQUIPMENT LOCATED IN MACHINE ROOM REPROGRAMMABLE INPUTS FOR FLOOR MESSAGE SIGNALS EG Hall Lanterns Car Direction Scrolling Messages Speech Announcements Discrete Binary Gray Code SIGNAL R...

Страница 6: ...ifying the current floor being edited Generally the bottom floor is 01h 00h represents no or invalid floor but may be configured as a floor Press Red to move backwards Press Black to move forwards Flo...

Страница 7: ...Press Black to move forwards Refer to the program of the indicator for NO ENTRY symbol capability To display a NO ENTRY symbol on a dot matrix indicator for the Landing or Both message display types...

Страница 8: ...Wire Mk 3 protocol only works with the latest 2 Wire devices and provides additional functionality over Mk 2 such as next stop floor address advanced hall lanterns signals rear door signals destinati...

Страница 9: ...stem FireFly Background R 000 G 000 B 000 BACK NEXT Mk 3 Custom Configure System FireFly Foreground R 255 G 255 B 255 BACK NEXT Mk 3 Configure System FireFly Layout Col Flr and Col LH BACK NEXT Mk 3 B...

Страница 10: ...n Press Red to move to the previous menu option Press Green to cycle the option forwards Press Yellow to cycle the option backwards To return to normal mode press Black repeatedly until the save menu...

Страница 11: ...m DO No BACK NEXT Configure Inputs Trigger for Doors No BACK NEXT Configure Inputs Hush Input No BACK NEXT 01 or more messages Configure Inputs Floor Trigger Delay 00 0 5s BACK NEXT Configure Inputs N...

Страница 12: ...will be provided for the advanced hall lantern If the advanced hall lantern inputs are Auto then the advanced hall lantern signals will either be taken from the normal lantern inputs when the current...

Страница 13: ...a full hall lantern arrow or hidden altogether If configured as a small car direction arrow the floor designation can be fixed off centre to leave space for the arrow when it is not visible Otherwise...

Страница 14: ...or Input type During test mode the floor trigger delay is fixed at 0 seconds to announce the current floor Car Mode dipswitch 5 on dipswitch 6 off The test mode will run up down the programmed floors...

Отзывы: