Re
-
Configuring the 16 IND055 Inputs
Re
-
Configuring System
From
“
Normal Mode
”,
press the Red and Black buttons together three times (or once from the
message programming menu) to enter the system configuration menu:
Configure System
2
-
Wire Output Type
2
-
Wire Mk.3
BACK
NEXT
Coloured menu button functions:
Press
Black
to move to the next menu option.
Press
Red
to move to the previous menu option.
Press
Green
to cycle the option forwards.
Press
Yellow
to cycle the option backwards.
To proceed to the input configuration menu,
press
Black
repeatedly until the save menu is
displayed, and then press the
Green
button to
save and continue.
continued on next page...
The first page in the Configure System menu is used to set the 2
-
Wire output type.
The
2
-
Wire Mk.3
protocol only works with the latest 2
-
Wire devices, and provides additional functionality
over Mk.2, such as next stop floor address, advanced hall lanterns signals, rear door signals, destination
control floor call signals, FireFly TFT configuration overrides, and more.
The
2
-
Wire Mk.2
mode allows legacy 2
-
Wire devices to function, but disables all of the features that
require the 2
-
Wire Mk.3 protocol.
The
2
-
Wire Mk.2 + Mk3
mode should allow a mixture of latest and legacy 2
-
Wire devices to function on a
single 2
-
Wire bus, with all Mk.3 features available to the latest devices. The update response times may be
reduced in this mode however, and so it is not advised for use on fast travelling lifts.
For the rest of the system and input configuration menus, any menu pages shown subsequently in this
manual with the
symbol will only be displayed if the 2
-
Wire Output Mode is set to either
“2
-
Wire Mk.3
”
or
“2
-
Wire Mk.2 + Mk.3
”.
Configure System Menu
Configure System
2
-
Wire Output Type
2
-
Wire Mk.3
BACK
NEXT
Mk.
3
2
-
Wire Output Type
select from:
2
-
Wire Mk.3
2
-
Wire Mk.2
2
-