Page 9
www.drucegrove.com
Tel: +44 (0) 1992 650486 Fax: +44 (0) 01992 652226
Drucegrove Ltd
,
6 Printers Way, Harlow, Essex, CM20 2SD, UK
Reconfiguring the 16 IND055 Inputs
Re
-
Configuring System
Continued from previous page...
Based on the 2
-
Wire Output Type selection, use the flow diagram below to complete the system
programming modifications:
Configure System
2
-
Wire Output Type
2
-
Wire Mk.3
BACK
NEXT
Configure System
Car Direction Arrows
Auto (Default)
BACK
NEXT
Mk.
3
Set Via Dipswitches
2-Wire Output Type is
2-Wire Mk.2
Configure System
FireFly Config
Set Via Dipswitches
BACK
NEXT
Mk.
3
2-Wire Output Type is
2-Wire Mk.3
or
2-Wire Mk2. + Mk.3
Configure System
FireFly Colour
Blue
BACK
NEXT
Mk.
3
Override Dipswitches
Configure System
FireFly Background
R:000 G:000 B:000
BACK < >
NEXT
Mk.
3
Custom
Configure System
FireFly Foreground
R:255 G:255 B:255
BACK < >
NEXT
Mk.
3
Configure System
FireFly Layout
Col Flr and Col LH
BACK
NEXT
Mk.
3
Blue
Black
Green
Red
Yellow
Purple
Brown
Teal
Configure System
Free Car Mode
Auto (Default)
BACK
NEXT
Mk.
3
Configure System
Lantern Arrows
Auto (Default)
BACK
NEXT
Mk.
3
Configure System
Adv Lantern Arrows
Auto (Default)
BACK
NEXT
Mk.
3
Configure System
Adv Lantern PI Mode
Auto (Default)
BACK
NEXT
Mk.
3
Configure System
Gong On Adv Lantern
No
BACK
NEXT
Mk.
3
Configure Inputs
Save & Continue
BACK SAVE
Press the
Red
button to return to
the start of the input
configuration menu
Press the
Green
button to save and
continue to the input
configuration menu
Configure System
2
-
Wire Output Delay
Disabled
BACK
NEXT
REFER TO
PAGE 12
REFER TO
PAGE 12
REFER TO
PAGE 13
REFER TO
PAGE 13
REFER TO
PAGE 13
REFER TO
PAGE 13
REFER TO
PAGE 13
REFER TO
PAGE 13