Page 14
www.drucegrove.com
Tel: +44 (0) 1992 650486 Fax: +44 (0) 01992 652226
Drucegrove Ltd
,
6 Printers Way, Harlow, Essex, CM20 2SD, UK
Scroll Speeds, Energy Saving Mode & Test Mode
Dipswitch Settings
In
“
Normal Mode
”
the 8
-
way dipswitch on the IND055 determines the scrolling value (0 to F) for an indicator
floor change, which can be modified by using dipswitches 1 to 4 to give the speeds below:
There is an 8
-
way dipswitch on the IND055 next to the reprogrammable inputs; it has various different
functions that are described below:
Dipswitch Number
Scrolling
Value
1
2
3
4
0
0
0
0
0
No Scrolling
0
0
0
1
1
Fastest Scrolling Speed
0
0
1
0
2
0
0
1
1
3
0
1
0
0
4
0
1
0
1
5
0
1
1
0
6
0
1
1
1
7
1
0
0
0
8
1
0
0
1
9
1
0
1
0
A
1
0
1
1
B
1
1
0
0
C
1
1
0
1
D
1
1
1
0
E
1
1
1
1
F
Slowest Scrolling Speed
If scrolling car direction arrows are required turn dipswitch 8 on. The active scrolling value setting from 1 to 15
will then apply to arrows also.
Dipswitch 5 selects the test mode, with the letters
”
Tst
”
replacing the Floor Input type. During test mode the
floor trigger delay is fixed at 0 seconds to announce the current floor.
Car Mode
(dipswitch 5 on, dipswitch 6 off): The test mode will run up & down the programmed floors to the
maximum floor value set by the user, floor positions and car directions being shown on the LCD display. After
every 4th floor change an allocated programmed message will scroll twice and then proceed to the next floor
position. If a Digitalker
®
speech unit is connected it will announce the relevant pre
-
programmed floor and
message speech codes. Thus floor designations, Indicators, and Digitalker
®
speech units can be tested
without using any input signals.
Hall Lantern Mode
(dipswitch 5 & 6 on): Whilst in test mode, turning on dipswitch 6 allows the hall lantern
functionality of an indicator to be tested. The car direction signal is taken away at every floor and an
appropriate hall lantern arrow will be set, allowing gongs and hall lanterns to be tested individually for each
floor.
(0 = OFF, 1 = ON)
To disable the energy saving mode (normally active when OFF) for indicators, gongs, hall lanterns &
Digitalker
®
speech units that have this feature set dipswitch 7=ON.
Floor / Arrow Scrolling
Energy Saving Mode
2
-
Wire System Test Mode