Eng
lish
INSTALLATION MANUAL
!Caution
When installing a built-in appliance, always take the following into account:
•
The minimum construction measurements according to Appendix 3, Fig. 1 and 2.
•
The construction height of the appliance.
Ø
Provide a gas connection at the location. For details, see section 5.2.
Ø
Make a passage for the concentric system; for details, see section 5.8.3.
!Caution
Additional instructions for the appliance to be installed can be found from section 5.10.
5.5 Placing a built-in appliance
(if applicable)
Not all built in DRU appliances are supplied with a control hatch.
!Caution
Built in appliances must be installed with the DRU control hatch. This is necessary to ensure a durable, safe and
proper operation. The DRU control hatch can be ordered separately. Exceptions are:
Appliances with supplied DRU guard cabinet. The DRU guard cabinet is intended for installation with a suspended
platform. If the appliance will be connected to the DRU PowerVent system, the DRU control hatch has to be used
after all.
The gas control is mounted to the appliance. It must be taken out and placed in the control hatch at a later time.
For placing the gas control in the control hatch, see section 5.7.
Proceed as follows:
Ø
Loosen the bracket with the gas control by loosening the self-tapping screws and screw the self-tapping screws
back in the appliance.
Ø
Place the bracket with gas control, together with the wiring of the ignition/ionisation cable(s), the flexible gas
hose(s) and type plate with chain in the direction of the control hatch.
!Caution
The data plate should remain connected to the chain.
Ø
Set the height of the appliance using the adjustable feet.
Ø
Make the appliance level at the same time.
!Tip
The construction frame can be adjusted afterwards for most 2- or 3 sided appliances. This allows a good contact of
the construction frame with the chimney breast. Adjustment should take place before the appliance is built in.
After building in, adjustment is no longer possible. For 2- or 3-sided appliances that cannot be adjusted, we refer
to section 5.10 'Additional instructions'.
!Caution
Do not ignite the appliance before the gas, discharge and electric connections have been fully installed, first
observe the procedure described in chapter 7.3.
5.6 Placing the chimney breast
(if applicable)
For a good heat discharge and operation of the appliance, there should be sufficient space around the appliance.
The chimney breast should be ventilated sufficiently by means of ventilation holes (incoming and outgoing).
!Caution
When an appliance is built in the floor, please take into account the minimum distances from a combustible
floor. If applicable, additional information about this is provided from section 5.10 'Additional instructions'.
7
Содержание Metro 130XTL RCH
Страница 29: ...E n g l i s h INSTALLATION MANUAL 29 38C 1868 d 0 0 8 4m 0 5m 38c 744zi 1x90 5 4 ...
Страница 31: ...E n g l i s h INSTALLATION MANUAL 31 S T 38c 1655 0 R U 55 38c 1656 0 15 14 ...
Страница 32: ...E n g l i s h INSTALLATION MANUAL 32 38C 1977 0 L 8x 16a ...
Страница 34: ...E n g l i s h INSTALLATION MANUAL 34 38P 0169 C B D E F G H A 38p 0443 25 24 ...
Страница 35: ...E n g l i s h INSTALLATION MANUAL 35 38P 0442 A C B E 38p 0444 D F G H 38P 0445 26a 26b 26c ...
Страница 36: ...E n g l i s h INSTALLATION MANUAL 36 38P 0446 38P 0447 38p 0448 38c 1657 0 28 27a 27b 29a ...
Страница 40: ...E n g l i s h DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven UK ...