Eng
lish
INSTALLATION MANUAL
5. Installation
5.1 Type of gas
The data plate indicates for which type of gas, gas pressure and for which country this appliance is intended.
The data plate can be found on the appliance or can be attached to a chain to which it should remain attached.
!Caution
Check whether the appliance is suitable for the type of gas and gas pressure used at the location.
5.1.1 Reconstruction to different type of gas
In order to convert this appliance to a different type of gas, please contact DRU's service department and ask for
the possibilities.
5.2 Gas connection
Place a gas tap in the gas pipe in accordance with the applicable regulations.
The gas connection on the gas control is located next to the receiver (see Appendix 3, fig. 38 (G)).
!Caution
Make sure there is no dirt in gas pipes and connections.
The following requirements apply to the gas connection:
•
Use a gas pipe with the correct dimensions, so that no pressure loss can occur.
•
The gas tap must be approved (in the EU this will be the CE mark).
•
You should always be able to reach the gas tap.
5.3 Electric connection
In case of a 230 Volt electrical connection, provide proper grounding. Place this electrical connection away from
the appliance, as low as possible in the chimney breast. This has to do with the temperature development in the
chimney breast.
!Caution
•
Protect the gas control and electric components, hereafter referred to as the gas control, against building
dust and moisture!
•
For connecting the receiver and control panel at an appliance equipped with the CM system
®
, you must
observe the instructions in the supplied manual.
5.3.1 Connecting the switch contact
(if applicable)
It is possible to operate one or more lamps (in case of several lamps, a maximum of 8A/250VAC/30VDC) via the
remote control of the appliance. You could think of the lamps of Dru's lux elements. For this, you can use switch
contact B on the receiver (see appendix 3, fig 36). The switch contact is not polar sensitive.
5.3.2 Connecting the Dru Omivent
(if applicable)
If the appliance is equipped with a Dru Lux Omnivent system, it can be operated with the remote control and
connected (see appendix 3, fig 36, (C)). The supply to this connection is equal to the mains voltage.
5.4 Placing the appliance
!Caution
•
Place the appliance in front of a heat-resistant and non combustible wall. The wall brackets on a built-in
appliance ensure that the minimum distance to the wall is maintained.
•
Ensure there are no combustible objects or materials present in the fire's radiation range, within a distance of
500 mm, unless indicated otherwise.
•
Place the concentric system in such a way that no fire hazard is ever created (also see section 5.8).
•
Take sufficient measures to prevent temperature of a wall behind the chimney breast becoming too high,
including the materials and/or objects behind the wall.
•
Do not cover the appliance and/or do not wrap it in an insulation blanket or any other material.
•
Make sure that the appliance to be installed has a stable position. Fasten possible extending legs with the
self-tapping screws.
6
Содержание Metro 130XTL RCH
Страница 29: ...E n g l i s h INSTALLATION MANUAL 29 38C 1868 d 0 0 8 4m 0 5m 38c 744zi 1x90 5 4 ...
Страница 31: ...E n g l i s h INSTALLATION MANUAL 31 S T 38c 1655 0 R U 55 38c 1656 0 15 14 ...
Страница 32: ...E n g l i s h INSTALLATION MANUAL 32 38C 1977 0 L 8x 16a ...
Страница 34: ...E n g l i s h INSTALLATION MANUAL 34 38P 0169 C B D E F G H A 38p 0443 25 24 ...
Страница 35: ...E n g l i s h INSTALLATION MANUAL 35 38P 0442 A C B E 38p 0444 D F G H 38P 0445 26a 26b 26c ...
Страница 36: ...E n g l i s h INSTALLATION MANUAL 36 38P 0446 38P 0447 38p 0448 38c 1657 0 28 27a 27b 29a ...
Страница 40: ...E n g l i s h DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven UK ...