5.8 Concentric system
5.8.1 General
The appliance is connected to a flue gas discharge / combustion air supply system delivered by DRU, hereafter
referred to as the concentric system. The diameter for this connection is indicated in appendix 2, table 2. The
passage to the outside can be created with a wall terminal (C11) or a roof terminal (C31). If necessary, an existing
chimney can be used (see section 5.8.4).
!Caution
•
Only use the concentric system supplied by DRU. This system has been tested in combination with the
appliance. DRU cannot guarantee a proper and safe operation of other systems and does not accept any
responsibility or liability for this.
•
Use a chimney set for the connection to the chimney, DRU will be able to supply it.
•
DRU's concentric system is intended for indoor use and may therefore not be used outdoors, with the
exception of the sections intended for that purpose such as roof and wall terminals.
The concentric system is constructed from (the flue spigot of) the appliance.
If, due to constructional circumstances, the concentric system is placed first, it is possible to connect the appliance
by means of a telescopic pipe piece.
5.8.2 Construction of the concentric system
Depending on the configuration of the concentric system, the appliance must be further adjusted with a possible
restrictor slide and/or air inlet guide.
See Tables 4 and 6 for determining the correct adjustment and section 'Adjustment of the appliance' for the
method of working.
The concentric system with wall or roof terminal has to comply with the following conditions:
•
In appendix 2, table 4 or 5 you can find whether a concentric pipe should be connected and what the
minimum vertical length would have to be.
•
Determine the permissibility of the required configuration.
When using a
wall terminal (C11)
the following applies:
•
The total vertical pipe length, when using a wall terminal, may have a maximum length that can be found in
appendix 2, table 4.
•
The minimum vertical pipe length, when using a wall terminal, can be found in appendix 2, table 4.
•
The total horizontal pipe length, when using a wall terminal, may have a maximum length that can be found
in appendix 2, table 4 (excluding wall terminal; see appendix 3, fig. 5).
When using a
roof terminal (C31)
the following applies:
•
The construction of the chosen system, when using a roof terminal, must be permissible according to
Appendix 2, Table 5 (See the method of working described below).
The working method below indicates how the permissibility is determined of a concentric system when using a
roof terminal.
1) Count the number of 45° and 90° bends required (15° and 30° bends are also allowed).
2) Count the total number of whole metres of horizontal pipe length.
3) Count the total number of metres of vertical and/or sloping pipe length (roof terminal excluded).
4) In the first 2 columns of Table 5, look for the number of bends required and the total horizontal pipe length.
5) In the top row of Table 5, look for the required total vertical and/or sloping pipe length.
6) A box with a letter means that the chosen concentric system is permitted.
7) Use Table 6 to determine how the appliance should be adjusted.
10
Содержание Metro 130XTL RCH
Страница 29: ...E n g l i s h INSTALLATION MANUAL 29 38C 1868 d 0 0 8 4m 0 5m 38c 744zi 1x90 5 4 ...
Страница 31: ...E n g l i s h INSTALLATION MANUAL 31 S T 38c 1655 0 R U 55 38c 1656 0 15 14 ...
Страница 32: ...E n g l i s h INSTALLATION MANUAL 32 38C 1977 0 L 8x 16a ...
Страница 34: ...E n g l i s h INSTALLATION MANUAL 34 38P 0169 C B D E F G H A 38p 0443 25 24 ...
Страница 35: ...E n g l i s h INSTALLATION MANUAL 35 38P 0442 A C B E 38p 0444 D F G H 38P 0445 26a 26b 26c ...
Страница 36: ...E n g l i s h INSTALLATION MANUAL 36 38P 0446 38P 0447 38p 0448 38c 1657 0 28 27a 27b 29a ...
Страница 40: ...E n g l i s h DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven UK ...