INSTALLATION MANUAL
!Caution
The yellow wire is the + pole, the black wire is the - pole. Always connect ‘- to -‘ and ‘+ to +’ .
6.2.2 Wireless
The wireless connection is divided into 2 types:
•
Connection via a ‘modbus’ protocol.
•
Control via an application.
!Caution
Only 1 type of wireless connection is possible on the communication module.
6.2.2.1 Connection via ‘modbus’ protocol
Wireless connection of a Domotics system to the receiver is possible via a connection according to the ‘modbus’
protocol. Such a connection can only be established with a communication module (see Appendix 3, fig. 35 (W)).
This module can be ordered from DRU. This communication module translates the ‘modbus’ protocol from the
Domotics system into a wireless signal to the receiver.
When connecting a Domotics system via the communication module to the receiver, proceed as follows:
Ø
Use the remote control to test whether the location where the communication module will be placed is within the
reach of the receiver.
Ø
Place the remote control on this location and test the reception sensitivity (RSSI).
Ø
Press the on/off button and down arrow at the same time. The value that is now visible, must be between -20 and
-70 (see User Manual, "Reception Sensitivity"). If needed, hold the remote control closer to the appliance in order
to improve the reception.
Ø
Connect the communication module by means of an RJ45 plug, according to the instructions in the manual that is
supplied with this module.
Ø
Now follow the steps described in the ‘modbus’ protocol manual. It is available from the supplier of the domotics
system.
6.2.2.2 Control via application
Also when operating the appliance via a tablet provided with the DRU Control App (iOS or Android), you will need
a communication module. This module can be ordered from DRU.
In order to control the fire via an application, proceed as follows:
Ø
Using the remote control, test whether the location where you want to place the communication module is within
the receiver's range.
Ø
Place the remote control on this location and test the reception sensitivity (RSSI).
Ø
Press the on/off button and down arrow at the same time. The value that is now visible, must be between -20 and
-70 (see User Manual, "Reception Sensitivity"). If needed, hold the remote control closer to the appliance in order
to improve the reception.
Ø
Connect the communication module by means of an RJ45 plug, according to the instructions in the manual that is
supplied with the communication module.
Ø
Use the instructions for the application in order to install it.
!Caution
•
The DRU Control app functions in accordance with the multicast and communication protocol. Ensure the
router is equipped with this. For this, consult the router's installation manual.
•
If the DRU Control app is used, the thermostat function no longer applies.
The application 'DRU Control' is available in the AppStore, at GooglePlay or our website: www.drufire.co.uk
17
Содержание Metro 130XTL RCH
Страница 29: ...E n g l i s h INSTALLATION MANUAL 29 38C 1868 d 0 0 8 4m 0 5m 38c 744zi 1x90 5 4 ...
Страница 31: ...E n g l i s h INSTALLATION MANUAL 31 S T 38c 1655 0 R U 55 38c 1656 0 15 14 ...
Страница 32: ...E n g l i s h INSTALLATION MANUAL 32 38C 1977 0 L 8x 16a ...
Страница 34: ...E n g l i s h INSTALLATION MANUAL 34 38P 0169 C B D E F G H A 38p 0443 25 24 ...
Страница 35: ...E n g l i s h INSTALLATION MANUAL 35 38P 0442 A C B E 38p 0444 D F G H 38P 0445 26a 26b 26c ...
Страница 36: ...E n g l i s h INSTALLATION MANUAL 36 38P 0446 38P 0447 38p 0448 38c 1657 0 28 27a 27b 29a ...
Страница 40: ...E n g l i s h DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven UK ...