Eng
lish
INSTALLATION MANUAL
!Caution
•
Always wait 5 minutes before re-igniting the appliance.
•
No changes may be made to the gas control.
7.3.2 Main burner
!Caution
•
The ignition electrode should ignite the main burner within a couple of seconds and without popping.
•
The main burner(s) must cross the full burner smoothly and without popping and continue to burn.
•
If the appliance does not ignite after three restarts and enters hard lockout, it may never be reset by
disconnecting it from the power supply. If a restart is necessary after all: remove the glass pane and make sure
the gas is able to escape from the appliance. After this, the appliance may be disconnected from the power
supply for 10 seconds. After these 10 sec., the power supply may be reconnected. Ignite the appliance in the
same way as the first ignition, as indicated in section 7.3.1.
Ø
Check operation of the main burner from a cold condition.
Ø
If sparks are determined between the ignition electrodes, the main burner should burn within a few seconds.
!Tip
The flame picture and a good flame transfer can only be properly judged if the glass window is installed.
Use the malfunction search diagram (Appendix 1) if the ignition of the main burner does not comply with the
above-mentioned requirements.
7.4 Flame picture
The flame picture can only really be assessed when the appliance has been burning for several hours. Volatile
components from paint, materials, etc., which evaporate in the first hours, will affect the flame picture.
Ø
Check whether the flame picture is acceptable.
Ø
Consult the malfunction search diagram (Appendix 1) if the flame picture is not acceptable, in order to solve the
problem.
8. Maintenance
Once per year, the appliance must be checked, cleaned and, if necessary, repaired by a competent installer in the
field of gas heating and electricity. Check at least whether the appliance is working properly and safely.
!Caution
•
Close the gas tap when performing maintenance work.
•
Check the gastightness after repair.
•
Make sure there is no voltage on the appliance.
Ø
Clean glass pane(s), if necessary.
!Caution
Only clean a glass pane once it has reached room temperature.
Caution!
•
Avoid damage to the glass pane(s).
•
Avoid/remove fingerprints on the glass pane(s), as they will burn into the glass.
•
Only clean glass pane(s) with DRU glass pane cleaner, as other agents may damage and/or deteriorate the
glass pane(s). For more information, visit our website www.dru.nl or ask your dealer.
•
Only use a microfibre cloth. Other materials such as (kitchen) paper, steel wool, etc. may cause scratches and
damage the coating in case of anti-reflective glass pane(s).
•
Regularly remove accumulated dirt, as it can burn into the glass.
•
Do not use the appliance when a pane is broken and/or cracked, until it has been replaced as described from
section 5.10.
!Caution
If necessary, place back the wood or pebble set correctly; for this, see from section 5.10.
Ø
Inspect the flue gas discharge system.
!Caution
You must always perform a final inspection.
Ø
Perform the inspection as described in chapter 7.
19
Содержание Metro 130XTL RCH
Страница 29: ...E n g l i s h INSTALLATION MANUAL 29 38C 1868 d 0 0 8 4m 0 5m 38c 744zi 1x90 5 4 ...
Страница 31: ...E n g l i s h INSTALLATION MANUAL 31 S T 38c 1655 0 R U 55 38c 1656 0 15 14 ...
Страница 32: ...E n g l i s h INSTALLATION MANUAL 32 38C 1977 0 L 8x 16a ...
Страница 34: ...E n g l i s h INSTALLATION MANUAL 34 38P 0169 C B D E F G H A 38p 0443 25 24 ...
Страница 35: ...E n g l i s h INSTALLATION MANUAL 35 38P 0442 A C B E 38p 0444 D F G H 38P 0445 26a 26b 26c ...
Страница 36: ...E n g l i s h INSTALLATION MANUAL 36 38P 0446 38P 0447 38p 0448 38c 1657 0 28 27a 27b 29a ...
Страница 40: ...E n g l i s h DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven UK ...