5.11.4 Placing glass panes
Placing the glass panes will take place in reverse order of the removal procedure described above.
!Caution
•
The DRU logo should be in the bottom right corner.
•
The self-tapping screws should not be over-tightened, since otherwise they could break or strip the thread:
tight=tight.
•
Make sure that the glass panes fit well together.
When mounting the side glass pane, you must proceed in reverse order.
!Caution
When mounting the side glass pane, you must carefully place the springy window strips in front of the glass pane
again, in order to avoid damaging the glass pane.
5.12 Adjustment of the appliance
The appliance has to be set in such a way that it works correctly in combination with the discharge system applied.
For that purpose, a restrictor slide is placed and/or the air inlet guide is removed. The conditions for application
with wall terminal and roof terminal are stated in Appendix 2, Tables 4, 5 and 6.
5.12.1 Restrictor slide
The restrictor slide (R) is supplied separately (see Appendix 3, fig. 14).
It is mounted as follows:
Ø
Unscrew the 10 self-tapping screws (S) from the middle plate (T) and remove them.
Ø
Place the restrictor slide.
Ø
Adjust the distance of the restrictor.
•
in case of a 40 mm setting, the restrictor slide is closed to a maximum level;
•
in case of a 55 mm setting, the distance must be set by means of a gauge (see Appendix 3, fig. 15).
Ø
Fix the restrictor slide by using the allen screw (U).
Ø
Remount the middle plate by using the self-tapping screws.
5.12.2 Air inlet guide
The air inlet guide (L) is at the back, below the combustion chamber (see Appendix 3, fig. 16a). In order to reach it,
you must remove the vermiculite tray. Ex works, the air inlet guide is mounted with an opening of 13 mm.
If table 4 and 6 in Appendix 2 indicate that the air inlet guide must be changed, please proceed as follows;
Ø
First remove the vermiculite tray.
•
Unscrew the self-tapping screws around the burner.
•
Remove the vermiculite tray.
Ø
Remove the air inlet guide (L).
•
Unscrew the self-tapping screws of the air inlet guide.
•
Remove the air inlet guide (L).
!Caution
Screw the self-tapping screws of the air inlet guide back in the appliance.
13
Содержание Metro 130XTL RCH
Страница 29: ...E n g l i s h INSTALLATION MANUAL 29 38C 1868 d 0 0 8 4m 0 5m 38c 744zi 1x90 5 4 ...
Страница 31: ...E n g l i s h INSTALLATION MANUAL 31 S T 38c 1655 0 R U 55 38c 1656 0 15 14 ...
Страница 32: ...E n g l i s h INSTALLATION MANUAL 32 38C 1977 0 L 8x 16a ...
Страница 34: ...E n g l i s h INSTALLATION MANUAL 34 38P 0169 C B D E F G H A 38p 0443 25 24 ...
Страница 35: ...E n g l i s h INSTALLATION MANUAL 35 38P 0442 A C B E 38p 0444 D F G H 38P 0445 26a 26b 26c ...
Страница 36: ...E n g l i s h INSTALLATION MANUAL 36 38P 0446 38P 0447 38p 0448 38c 1657 0 28 27a 27b 29a ...
Страница 40: ...E n g l i s h DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven UK ...