ELECTRICAL
SECTION 8
Page 43
DRESSTA
TD-25M EXTRA
CRANKING MOTOR 42 MT
The solenoid windings are energized and the resulting plunger and shift lever movement causes
the pinion to engage the engine flywheel ring gear and the solenoid main contacts to close, and
cranking takes place. When the engine starts, pinion overrun protects the armature from excessive
speed until the switch is opened, at which time the return spring causes the pinion to disengage.
To prevent excessive overrun and damage to the drive and armature windings, the switch must be
opened immediately when the engine starts.
A cranking period for all types of motors should never exceed 30 seconds without stopping to allow
the motor to cool.
24. TROUBLESHOOTING THE CRANKING CIRCUIT
If the cranking system is not performing properly, make the following check to help determine
which part of the circuit is at fault.
a. Battery
To determine the condition of the battery, follow the testing procedure outlined in this Section,
BATTERY. Insure that the battery is fully charged.
The wiring, switches, and cranking motor
cannot be checked if the battery is defective or discharged.
b. Wiring
Inspect the wiring for damage. Inspect all connections to the cranking motor, solenoid, magnetic
switch, any other control switch, and battery, including all ground connections. Clean and tighten
all connections as required.
The cranking system cannot operate properly with excessive resistance in the circuit.
c. Magnetic Switch, Solenoid and Control Switches
Inspect all switches to determine their condition. From the Electrical Dozer System determine
which circuits should be energized with the starting switches closed. Use a voltmeter to detect any
open circuits.
d. Motor
If the battery, wiring and switches are in satisfactory condition, and the engine is known to be
functioning properly, remove the motor and follow the test procedures outlined below.
A cranking motor is designed for intermittent duty only, and should never be operated for more
than 30 seconds at a time. After 30 seconds, the cranking must be stopped for at least two minutes
to allow the motor to cool.
With the cranking motor removed from the engine, the armature should be checked for freedom of
rotation by prying the pinion with a screwdriver. Tight bearings, a bent armature shaft, or a loose
pole shoe screw will cause the armature does not turn freely. If the armature does not turn freely
the motor should be disassembled immediately. However, if the armature does rotate freely, the
motor should be given a no-load test before disassembly.
Содержание TD-25M EXTRA
Страница 1: ...SMTD25MEX07 1E SERVICE MANUAL TD 25M EXTRA SERIAL NUMBERS 75001 AND UP DRESSTA ...
Страница 2: ......
Страница 4: ......
Страница 5: ...SECTION 1 INTRODUCTION ...
Страница 6: ......
Страница 8: ......
Страница 25: ...SECTION 5 STEERING ...
Страница 26: ......
Страница 27: ...STEERING SECTION 5 DRESSTA TD 25M EXTRA CONTENTS GENERAL 1 DESCRIPTION 1 ...
Страница 28: ......
Страница 30: ......
Страница 31: ...SECTION 6 COOLING SYSTEM ...
Страница 32: ......
Страница 34: ......
Страница 49: ...SECTION 7 DRIVE TRAIN ...
Страница 50: ......
Страница 52: ......
Страница 60: ......
Страница 62: ......
Страница 83: ...SECTION 7B HYDRAULIC TORQUE CONVERTER ...
Страница 84: ......
Страница 86: ......
Страница 89: ...HYDRAULIC TORQUE CONVERTER SECTION 7B Page 3 DRESSTA TD 25M EXTRA GENERAL Fig 7B 2 Exploded View of Tor ...
Страница 115: ...SECTION 7C TRANSMISSION ...
Страница 116: ......
Страница 208: ......
Страница 209: ...SECTION 7E STEERING DRIVE ...
Страница 210: ......
Страница 212: ......
Страница 251: ...SECTION 7F FINAL DRIVE ...
Страница 252: ......
Страница 254: ......
Страница 272: ......
Страница 273: ...SECTION 8 ELECTRICAL ...
Страница 274: ......
Страница 276: ......
Страница 283: ...ELECTRICAL SECTION 8 Page 7 DRESSTA TD 25M EXTRA Fig 8 1 Wiring Diagram earlier version ...
Страница 284: ......
Страница 285: ......
Страница 286: ...SECTION 8 Page 10 ELECTRICAL TD 25M EXTRA DRESSTA Fig 8 1A Wiring Diagram later version ...
Страница 331: ...SECTION 9 FRAME ...
Страница 332: ......
Страница 334: ......
Страница 336: ...SECTION 9 FRAME Page 2 TD 25M EXTRA DRESSTA GENERAL Fig 9 2 View of Frame ...
Страница 339: ...SECTION 10 HYDRAULICS ...
Страница 340: ......
Страница 342: ......
Страница 363: ...SECTION 10A PUMPS ...
Страница 364: ......
Страница 366: ......
Страница 387: ...SECTION 10B VALVES ...
Страница 388: ......
Страница 390: ......
Страница 403: ...VALVES SECTION 10B Page 13 DRESSTA TD 25M EXTRA PILOT PRESSURE VALVE Fig 10B 10 Exploded View of Pilot Pressure Valve ...
Страница 412: ......
Страница 413: ...SECTION 10C CYLINDERS ...
Страница 414: ......
Страница 416: ......
Страница 449: ...SECTION 10E RESERVOIRS AND FILTERS ...
Страница 450: ......
Страница 452: ......
Страница 459: ...SECTION 12 POWER ...
Страница 460: ......
Страница 462: ......
Страница 478: ......
Страница 479: ...SECTION 13 SUPERSTRUCTURE ...
Страница 480: ......
Страница 482: ......
Страница 491: ...SECTION 14 SUSPENSION ...
Страница 492: ......
Страница 542: ......
Страница 543: ...SECTION 15 TRACK OR WHEELS ...
Страница 544: ......
Страница 546: ......
Страница 565: ...SECTION 17 MOUNTED EQUIPMENT ...
Страница 566: ......
Страница 568: ......