5.1
Initial cleaning of the chemical protective
suit
1. Leave the contaminated area and have an assistant carry
out initial cleaning of the chemical protective suit. The
helper must also wear protective clothing and possibly
respiratory equipment. For initial cleaning Dräger
recommends using plenty of water with added cleaning
agents. This is the best way of washing off most chemicals
(acids, alkalines, organics and inorganics).
2. Clean the suit thoroughly for a sufficient time. Avoid
spreading the chemicals.
3. After contamination with hazardous materials the effluent
must be disposed of in accordance with the applicable
waste disposal regulations.
4. If necessary, carry out decontamination in several steps.
Contact Dräger for more information on cleaning.
5.2
Taking off the chemical protective suit
1. Have an assistant open the fastener system. Always pull
zipper tab in direction of zipper mechanism. Do not use
force.
2. Remove the left arm from the sleeve.
3. If the chemical protective suit is equipped with a ventilation
unit:
a. Open the integrated waist belt.
b. Have an assistant disconnect the air supply
1
.
4. If the chemical protective suit is equipped with D-connect:
a. Open the integrated waist belt.
5. If the chemical protective suit is equipped with a crotch
strap:
a. Detach the crotch strap from the waist belt of the self-
contained breathing apparatus.
6. Remove the right arm from the sleeve.
7. Bend your knees slightly.
8. Fold the chemical protective suit away from the equipment
bearer in such a way that no fluids can enter the interior of
the suit.
9. Step out of the boots and trouser legs.
10. Take off safety helmet, self-contained breathing apparatus,
full facepiece and cotton gloves.
6
Troubleshooting
WARNING
Never touch contaminated parts without protective
clothing. Avoid contaminating the clean interior of the
suit.
CAUTION
If precleaning is not possible on site, remove and close
suit immediately to prevent chemicals from entering
the suit.
WARNING
Wait to take off chemical protective suit until you reach
a non-contaminated area.
1
Observe the corresponding Instructions for Use.
!
!
!
NOTICE
Dräger recommends that you keep a record of the
mission (see Chapter 11 on Page 36).
Fastener system
jammed
Foreign object
in zipper
mechanism
Clean zipper
mechanism,
remove foreign
object
excess friction
Lubricate zipper
mechanism with
grease stick
Leak in chemical
protective suit
Fastener system
not closed
Close zipper
completely
Suit material
damaged
Repair with suit
repair kit
Safety boots or
gloves defective or
leaky joint
Replace or seal
and check for leaks
again
Dirty or defective
visor or seam
Clean or replace
and check for leaks
again
Visor or seam
leaky
Replace or seal
and check for leaks
again
Chemical
protective suit is
not ventilated
Valve sticks
Clean or replace
and check for leaks
again
Velcro tape
becomes detached
Velcro tape on
chemical
protective suit with
single flap is
attached with
adhesive.
Cleaning and
decontamination
can cause it to
become loose.
Reglue velcro tape
and check for leaks
again.
Fastener system
jammed
Foreign object in
zipper mechanism
Clean zipper
mechanism,
remove foreign
object
i
i
Содержание CPS 7900
Страница 2: ......
Страница 18: ...18 Dräger CPS 7900 Prüfprotokoll 11 Prüfprotokoll Anzug durchgeführte Prüfung geprüft von Datum Ergebnis ...
Страница 36: ...36 Dräger CPS 7900 Test protocol 11 Test protocol Suit performed test tested by date result ...
Страница 110: ...110 Dräger CPS 7900 Controlebericht 11 Controlebericht Gaspak Uitgevoerde controle Gecontroleerd door Datum Resultaat ...
Страница 127: ...Prøvningsprotokol Dräger CPS 7900 127 11 Prøvningsprotokol Dragt Gennemført kontrol Kontrolleret af Dato Resultat ...
Страница 145: ...Tarkastuspöytäkirja Dräger CPS 7900 145 11 Tarkastuspöytäkirja Puku Suoritettu tarkastus Tarkastaja Päivämäärä Tulos ...
Страница 163: ...Testprotokoll Dräger CPS 7900 163 11 Testprotokoll Drakt Utført kontroll Kontrollert av Dato Resultat ...
Страница 181: ...Testprotokoll Dräger CPS 7900 181 11 Testprotokoll Dräkt Utfört test Test utfört av Datum Resultat ...
Страница 200: ...200 Dräger CPS 7900 Protokół z badań 11 Protokół z badań Ubranie przeprowadzone badanie sprawdzał data Wynik ...
Страница 219: ...Журнал проверок Dräger CPS 7900 219 11 Журнал проверок Костюм вид проверки кем проведена проверка Дата Результат ...
Страница 257: ...Test protokolü Dräger CPS 7900 257 11 Test protokolü Giysi Yapılan test Testi yapan kişi Tarih Sonuç ...