Assembly
Connection
The
clarios
is supplied with DC power and dimmed via a separate PWM signal (pulse width mod
-
ulation). A PWM signal (S-PWM) is required for each light color. The PWM input has the following
characteristics:
The switching point of the luminary between on and off for the PWM level is not defined: Ideally it
should be worked with a switching impulse between ground and open contact or optionally with an
impulse between ground and operating voltage. A PWM signal differing from the operating voltage
is not allowed.
Free cabling
The connect is made according to the assignment tables. The connection must be carried out ac-
cording to the required IP classification.
Attention:
In case the luminary is used without the dimming function, the PWM line (wire for the
PWM signal) must be connected to ground (-). Otherwise the LED remains off.
Connection diagram of the clarios white / monochromatic without dimmer
See respective drawing in the middle of this manual (p. 14+15).
Connection diagram of the clarios white / monochromatic with dimmer
See respective drawing in the middle of this manual (p. 14+15).
Assembly
Attention:
The cable of the
clarios flex beam RGB
features a wire which is not used (brown or gray).
Normally, the wire is shortened ex works and should not be connected.
Connection diagram of the clarios flex beam RGB
See respective drawing in the middle of this manual (p. 14+15).
Connection diagram of the clarios flex beam RGBW
See respective drawing in the middle of this manual (p. 14+15).
M12 plug and cabling system
The connection of the
clarios
versions with M12 connector is quite simple, either with or without
dimming function. Plug the connector of the luminary in a free socket of the M12 cabling system.
The M12 cabling system is coded in a way to avoid wrong wiring or failures.
Please plan the components required for the electrical installation (power supplies, distributors,
extensions and plugs for unassigned M12 sockets) according to the sales documentation of the
M12 cabling system before placing an order.
Setting the flex beam (clarios flex beam only)
The
clarios flex beam
is provided with an adjustable lens with which the beam angle can be
changed between 10° and 45° (half beam angle, FWHM) after installation. Ideally the beam angle
is set in the dark with the cold, but switched on luminary.
22
23
en
en
PWM line connected to ground (-)
LED on
PWM line open
LED off
PWM line connected to operating voltage (+)
LED off
PWM frequency = 0 to 1,000 Hz
clarios white / monochromatic
Wire color
Assignment
red
+ 24 Volts
blue
S-PWM
black
ground (-)
clarios flex beam RGB
Wire color
Assignment
white
+ 12
red
red S-PWM
green
green S-PWM
blue
blue S-PWM
black
ground (-)
clarios flex beam RGBW
Wire color
Assignment
white
+ 12 Volts
red
red S-PWM
green
green S-PWM
blue
blue S-PWM
brown
white S-PWM
black
ground (-)
Assignment of the M12 connector system
Pin number
M12 plug
Wire color
(if plug is pinched off)
5-pin plug clarios
white / monochromatic
5-pin plug clarios
flex beam RGB
1
brown
24 V +
red S-PWM
2
white
24 V +
green S-PWM
3
blue
S-PWM
12 V +
4
black
Masse
blue S-PWM
5
green/yellow (gray)
ground
ground