Working environment and grounding
The flooring of the working area must be
anti-static according to DIN EN
50050-1:2014-03, measurement according
to DIN EN 1081:1998-04. The antistatic
flooring prevents electrostatic charges from
building up. Dangerous flashovers are pre-
vented.
4.2
Connecting
Personnel:
Operator
+ additional qualification high tension
technology
+ additional qualification explosion pro-
tection
Protective equipment:
Protective workwear
Anti-Static Safety Boots
1.
WARNING!
Sources of ignition may cause explo-
sions!
Ensure a non-explosive atmosphere.
Fig. 2: Connect compressed air supply
2. Bolt compressed air supply (3) to the
compressed air controller (2) of the elec-
trostatic controller (1).
Fig. 3: Ground electrostatic controller
3. Screw on grounding cable (5) to the
grounding bolt (4) of the electrostatic con-
troller (1). Connect with the grounding
point at the installation site.
Fig. 4: Connect connection cable
4. Screw on connection cable (6) to the
output (7) of the electrostatic controller
(1).
Assembly
11/2019
EcoGun AS MAN EC - MSG00022EN
8/52