6. Release trigger lever.
7. Clean air cap (4) using cleaning agent
and cleaning brush.
8. Dry cleaned air cap (4) using compressed
air (at max. 2bar).
9. Clean the nozzle (5) in the cleaning bath
using a soft brush.
Assembly
10. Insert and tighten nozzle (5).
Tightening torque: 10Nm
11. Fit air cap (4).
12. Hand-tighten cap nut (3).
8
Maintenance
8.1
Safety notes
DANGER!
High voltage
High voltage can be present on compo-
nents and cables. There is a risk of death
due to electric shocks and discharges.
Before carrying out any work:
– Switch off electrostatic controller.
– Discharge electrode by means of a
grounding rod. In this, pull the trigger
completely.
– Verify no current is present.
WARNING!
Risk of injury from unsuitable replace-
ment parts in explosive areas.
Replacement parts not compliant with the
explosion protection specifications can
cause explosions in an explosive atmos-
phere. Serious injuries and death can be
the consequence.
– Use exclusively original replacement
parts.
WARNING!
Danger to health from harmful or irri-
tant substances
Contact with hazardous liquids or vapors,
can result in serious injury or death.
– Ensure that the forced ventilation is
operational.
– Follow safety data sheets.
– Wear specified protective clothing.
WARNING!
Risk of injury due to escaping material
and compressed air
Escaping compressed material can cause
serious injury.
Before carrying out any work:
– Disconnect the system, in which the
spray gun is installed, from com-
pressed air and material supply.
– Secure the system against being
switched on again.
– Depressurize the lines.
Maintenance
11/2019
EcoGun AS MAN EC - MSG00022EN
20/52