dormakaba Canada Inc. RAC5 XT Installation Guide – PK3737 | 13
4.2.2 Mount the Contactless Card Reader
NOTE:
All readers are rated IP 54.
Do not exceed the maximum cable length indicated by the manufacturer of the products
being connected. Refer to the wiring label on the access door, the wiring diagram &
tables in Annex A, or the detailed peripherals connections in Annex B.
Every wire must pass through the strain relief as connected in the pre-installation
procedures.
1.
Remove the back plate and use it to mark the holes for the cables and screws.
NOTE:
Do not use the actual drawing from Annex E of this document to mark the hole locations as the
drawing is not to scale.
2.
Drill the holes in the wall according to the diameters indicated on the drilling template in Annex E, based
on the type of surface the reader is being installed on:
a)
Metal surface mounting: Install the back plate onto the wall with the metal screws provided in
the installation hardware bag
b)
Drywall surface mounting: Tap the wall inserts (provided in the installation hardware bag) into
the wall using a rubber mallet. Install the back plate onto the wall with the wood screws
provided
3.
Connect the included cable to the terminal block of the reader as shown in Annex A. Ensure the correct
wire colour is attached to the correct terminal block connection.
4.
Route the card reader’s wire through the grommet of the back plate and assemble the front of the reader
onto the back plate. Assemble by tightening down the screw (provided in the card reader’s installation
bag) on the bottom of the card reader.
5.
Connect the card reader wire to the terminal blocks of the controller PCB as per Annex A.
Ensure that the jumper wires are also connected on the controller PCB.
NOTE:
If required, to differentiate between the ingress and egress, ensure that the appropriate connector
on the controller PCB is used.
4.2.3 Connect Peripheral Wiring
Do not exceed the maximum cable length indicated by the manufacturer of the products
being connected. In addition, the wire used to connect the peripherals to the controller
PCB must be of the proper gauge and type as specified by the manufacturer. Refer to
the wiring label on the access door or the wiring diagrams in Annex B.
Every wire must pass through the strain relief as connected in the pre-installation
procedures. Follow the indications below for the different peripherals being connected.
The actual items to connect will vary based on the system configuration ordered.
4.2.3.1 Electric Strike or Electromagnetic Lock (Locking Device)
1.
Refer to Annex B for detailed wiring.
dormakaba Canada Inc. does not provide technical or field support for third party locking
devices. Please consult the device manufacturer for support.