12-2020
dormakaba Canada Inc. RAC5 XT Installation Guide – PK3737 | 7
(E)
Power & Battery Status LEDs: Provides visual indication of the operational status of the RAC5 XT system.
Battery status LED is only used on battery back-up equipped systems
(F)
Cam-lock with Key: To provide secure locking and to control access to the RAC5 XT enclosure
Optional Components:
(G)
Battery Back-up: 12 VDC battery providing up to 4 hours of operation in the event of a power failure
Not Shown:
(H)
Cables: Cables required for connections of the LEDs, power supply and controller PCB. If equipped, will
also include cable for connection of battery back-up
2.2.2 Contactless Card Reader
The Contactless Card Reader is a small, vertical-mounted unit that protrudes from the wall and is used with
RFID-based keycards.
Figure 4 – Contactless Card Reader
2.2.3 Locking Devices
The RAC5 XT controller PCB provides one or multiple relay outputs that can be used to control Electric Strikes
(K) or Electromagnetic Locks (L) as shown below.
Figure 5 – Electric Strike & Electromagnetic Lock