dormakaba USA Inc. System User Guide 7040.1121 Rev E 10/22 | 67
User Enable/
Disable:
#54
#54 _ _ (ID) _ _ _ _ _ _ (Combo) _ _ (User to
Change) 0
to Disable User
#54 _ _ (ID) _ _ _ _ _ _ (Combo) _ _ (User to
Change) 1
to Enable User
Master or Manager
Manager must be
managed by
Master
Keypad:
Lock:
User Enabled/Disabled
Edit User
Privileges:
#55
Open Only:
#55 _ _ (ID) _ _ _ _ _ _ (Combo)
_ _ (User to Change) 1
Master or Manager
Manager privileges
must be edited by
Master
Keypad:
Lock:
User Privilege changed
as identified
Delete User:
#56
#56 _ _ (ID) _ _ _ _ _ _ (Combo) _ _ (User
to Delete)
Master or Manager
Manager must be
deleted by Master
Keypad:
Lock:
User Deleted
Reset User
Combination:
#57
#57 _ _ (ID) _ _ _ _ _ _ (Combo)
_ _ (ID to Reset) _ _ _ _ _ _ (New Combo)
_ _ (ID to Reset) _ _ _ _ _ _ (New Combo)
Master or Manager
Manager must be
reset by Master
Combination
Length must meet
requirement
Keypad:
Lock:
User will have new
Initial Combination. User
should change combination
for first use.
Uninstall/Reinstall/Reset Keypad and Lock
The commands below are shown with the as the key press for waking the system. When not needed the lock
will respond with a short red flash and low beep signaling that the lock is ignoring that key and waiting for your
# command.
Action
Command String
Requirement
Result
Reinstall
Keypad:
#32
#32 _ _ (ID) _ _ _ _ _ _ _ _ (Combo) Open Privilege
Required
Keypad:
Alternating Red and
Green Flashes indicate the
same Keypad Model is not
paired, Success indicated with
Lock:
Lock is Installed to
Keypad
Uninstall
Lock:
#23
#23 00 (ID) _ _ _ _ _ _ _ _ (Combo) Master Only
Keypad:
Lock:
Is no longer installed to
Keypad, all settings are
maintained
Reset Lock:
#25
#25 00 (ID) _ _ _ _ _ _ _ _ (Combo) Master Only
Keypad:
Lock:
Master Combination is
reset to 12345678, All users
deleted, All Factory Defaults
restored, Lock will be uninstalled
from Keypad
Install Lock:
#22
#22 00 (ID) 12345678 (Combo)
Uninstalled: Master
Combination has been
changed from default
Keypad:
Lock:
Installed