dormakaba USA Inc. System User Guide 7040.1121 Rev E 10/22 | 16
Locks
Choose between Install, Uninstall, TL Schedule, Time
Delay configuration times, Time Delay Override
allowed and Reset.
FW Update
Enables a firmware update when connected to a PC
running the LA GARD software client.
*Not evaluated by UL
3.2.3 Using a Non-Display Keypad - # Commands
Below is a table outlining each # Command and their function for non-Display Keypads. For more details,
please refer to
(contains 701 model # commands) and
commands).
Table 3 – # Commands (non-Display Keypad)
3.3 System Functions
The System menu allows the User to view and change various aspects, such as Combination length, Buzzer and
Backlight, amongst other options. Below is a table that outlines Buzzer, LED, and Screen Messages in response
to certain events.
Table 4 – Buzzer, LED, and Screen Message(s)
Event
Buzzer
LED
Screen Message(s) (Display Only)
System wakeup
Short high beep
Short green flash
N/A
Set Combo Length
#11
Open PC Link
#30
Delete User
#56
Set User Mode
#12
Reinstall Keypad
#32
Reset User Combo
#57
Set Duress
(Silent Alarm)
#14
Set Backlight On/Off
#40
Observe DST
#63
Input Signal
Configure
#16
Set Buzzer On/Off
#41
Set Time/Date
#65
Force Combination
Change On/Off
#17
Add User
#50
Set Time Delay and
Open Windows Values
#72
Install Lock
#22
Change Own Combo
#52
Set TDO Allowance
#73
Uninstall Lock
#23
User Enable/Disable
#54
Cancel Time Delay
#74
Reset Keypad
#25
Set User Lock Privileges
#55
Enable FW Update
#99