dormakaba USA Inc. System User Guide 7040.1121 Rev E 10/22 | 41
3.
From the options, select “Locks”.
4.
Select “Reset”.
5.
All locks installed within the System will be listed. An X indicates no lock installed. Press the corresponding
number key to select a Lock.
6.
After resetting all other locks, or if the primary lock is the only one installed, “Confirm Reset” will appear on
screen. Select “Yes”. “Success” will appear on screen when the lock is reset. If the primary lock is reset, the
Keypad will then reset. If other locks are reset, the Keypad will return to the Locks section on screen.
Note:
An ‘X’ in the lock selection screen indicates the lock cannot be reset. The lock might not be connected, or
not installed, or is the primarily lock and the only one that can be reset. When the primary lock is the only lock
installed, a prompt will appear instead of lock selection to confirm the reset.
3.13.3.2 Master Reset – Non-Display Keypad
Follow these steps to perform a Master reset using a non-Display Keypad:
1.
Enter this # Command to perform a Master reset: #25<Master PIN><return key>.
2.
If the Master combination is unknown, proceed to the next section to perform a Mechanical Reset.
3.13.3.3 Mechanical Reset
A mechanical reset can be done utilizing the LA GARD Reset Box (Item/Order # 704065). Refer to the Reset
Box User Guide (Document #7039.0521) for more information. The Mechanical Reset is not UL evaluated.
It is important after the reset operation, that the Reset Box is disconnected from the operational lock. If the
safe door is closed with the reset box attached, the lock will no longer open.
3.14 Time Delay
During a Time Delay, the safe lock cannot be opened until the delay period expires. The Time Delay period
ranges from 00 (Disabled) to 99 minutes and can be set either via the Keypad or through the LA GARD
Software client. Once the Time Delay period is complete, the Confirmation Window period starts. During the
confirmation period, the user can re-authenticate to open the lock.
•
Keypads will provide continuous feedback to signify the Delay Period and Confirmation Window.
•
The Keypad will beep and flash a red LED once every 10 seconds during the Time Delay period.
•
The Keypad will then beep and flash a green LED once every 10 seconds during the Confirmation
Window, signifying the safe lock can now be opened.
•
Display Keypads provide additional on-screen feedback during the Delay Period and Confirmation
Window.
•
There are multiple ways to override the Time Delay period, if enabled. If Time Delay is enabled for a lock,
each valid User ID with a Combination will trigger the start of the time delay period if the intent is to
open the lock.
3.14.1 Enable/Disable Time Delay
3.14.1.1 Enable/Disable Time Delay – Display Keypad
Follow these steps to Enable/Disable Time Delay on a Display Keypad:
1.
Enter an Authorized User ID and Combination.