6050-065-C-2-16
2
5
4502-010
KEY SWITCH
DATA
9
10
11
12
13
14
15
ON
12345678
ON
12345678
NC
NO
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
Monitored
Photo Sensor
Potential
Entrapment
Area
DoorKing Access Control System (Model 1833, 1835, 1837 or
1838) tracker system can be connected.
This system can keep track of gate operator cycle count, shorted
inputs, loop detector problems, any forced entry attempts, if the
gate has struck anything during the open or close cycle, power
interruptions, etc.
For more detailed information
refer to the Tracker Board
Installation and Wiring
Manual, DoorKing P/N
2358-010.
Terminal 11 required only
if the tracker board will
activate the gate
operator. Refer to the
manual 2358-065 for
detailed information.
3
1 2
4 5 6 7 8
10
9
Gate Tracker
(Quad Box Shown)
DATA
Optional External
Alarm Reset
Button Connection
24 VAC Power
12 VAC Power
Auxiliary
Terminal
Monitored
Reversing
Edge
OPTIONAL Wireless Note:
Refer to the
instruction sheet that comes with the
receiver/transmitter for more specific
wiring and mounting instructions.
Mointored Sensor Note:
Only 1 monitored Device can
be connected to each input.
Mointored Sensor Note:
Inputs are active in both
directions of travel.
OPENING Gate Edge Activation:
Gate will reverse 2 inches and
STOP
.
Another input is needed to open gate.
CLOSING Gate Edge Activation:
Gate
will reverse back to open position.
Another input is needed to close gate.
When OPENING Gate’s Photo Beam gets Blocked:
Gate will stop
and reverse 2 inches. Another input is needed to open gate.
When CLOSING Gate’s Photo Beam gets Blocked:
Gate will reverse
back to open position. Another input is needed to
close gate.
12 or 24 VAC
Wireless Receiver
for Reversing Edge
250 ma
max
24 VAC
OR
12 VAC
Power
Com
To Com
To Reversing
Edge
Photo Beam
SW 2,
Switch 7
MUST
be
ON
.
SW 2,
Switch 8
MUST
be
ON
.
ON
123456
7
8
SW2
ON
1234567
8
SW2
External Entrapment Protection Devices:
In addition to the inherent reversing sensor
system, this operator has a 6-pin UL 325
terminal for the connection of
photo
sensors
-Type B1 and/or
reversing edges
-
Type B2 entrapment protection required by
UL 325 standards.
An external entrapment
protection device MUST be installed or the
operator will NOT function
. Inputs can be
selected for function by the DIP-switch
settings for SW 2 switches 7 & 8 on page 19.
4.3 Auxiliary Terminal Wiring
Alarm Output
Alarm Reset Input
Common
Tracker Data
Tracker Data
Tracker Data
Monitored UL 325 Photo Sensor
Common
Monitored UL 325 Revering Edge
Common
Содержание 6050-080
Страница 41: ...6050 065 C 2 16 37...