6050-065-C-2-16
10
1.3 Underground Conduit Requirements
1.4 Pad Mount
Sweeps
Concrete Pad
Primary
Operator
Position
Secondary
Operator
Position
22”
24”
24”
Depth of the concrete pad is
determined by soil conditions and
local building codes. Reinforced
concrete recommended.
Note: If allowed by local codes, the
top of the concrete pad can be flush
with ground level, which will allow
the gate bracket to be mounted
lower on the gate.
Arm
Rotation
Area
Gate Bracket Height
Concrete Pad Position
3/8
Secure the operator to the
concrete pad with four (4)
3/8” x 3” sleeve anchors
(not supplied).
Note: 2” thick
gate Illustrated.
Closed Gate
Open Gate
3”
Output
Shaft
3”
2.5”
2.5”
Right Support Leg
Left Support Leg
Operator MUST
be level.
Note: Right support leg removed from
this illustration to show conduit detail.
Low
Volt
High
Volt
Inter
connection
Cable
11”
Conduit
5”
9.5” 6”
43”
12”
Pad Support Base
Concrete Pad
14”
10”
90°
DoorKing’s Primary/Secondary Interconnection Cable (Dual Operator Application Only)
(Secondary Operator AC Power and Communication wires)
Loop Lead-In Wires (Low Voltage wire insulation)
AC Input Power (High Voltage wire insulation)
•
The conduit requirements are for a typical slide gate operator installation (the secondary operator is shown for those
applications where a secondary operator may be used).
The conduit requirements for your application may vary from this
depending on your specific needs.
•
Use only sweeps for conduit bends. Do not use 90° elbows as this will make wire pulls very difficult
and can cause damage to wire insulation. DoorKing recommends using 3/4-inch conduit.
• Installation of
External Entrapment Protection Devices
is REQUIRED (photo sensor and/or reversing edge).
•
Be sure that all conduits are installed in accordance with local codes.
•
Never
run low voltage rated wire insulation in the same conduit as high voltage rated wire insulation.
Elbow
NO
Sweep
YES
External Safety Devices, Controls and P.A.M.S. Wires (Low Voltage wire insulation)
Содержание 6050-080