Structure and Operation
D760.H03E-001.H1907
69
Turn on heater
1. Heating mode: use the heating button 1,
start the heater in the heating operation
mode (continuous operation), and the
indicator light of heater operation (red) lights
up. At the same time, the required
temperature can be adjusted by using the
pre-selected temperature knob 7;
2. Ventilation mode: use the ventilation button
5, start the heater in the ventilation
operation mode (continuous operation),
and the ventilation operation indicator light
(blue) lights up. At this time, knob 7 has no
adjustment function in the ventilation
operation.
Turn off the heater
Use the close button 3, the heating or ventilation operation ends, the correspond-
ing indicator light goes out, the heater runs 240s, the system stops working.
Precautions of using parking warm air
1. The heater must be turned off when refueling.
2. Do not use heater in closed rooms such as garages or parking buildings; The use
of heater in the formation of flammable vapors or dust is not permitted, such as
fuel warehouse, carbon warehouse, wood warehouse, granaries and similar sites.
3. The heater shall not operate in the area where the exhaust emission device is
located during the operation of the heater. If it is necessary to operate in the
exhaust emission device, the heater shall be turned off first until all parts are
completely cooled and protective gloves are put on when necessary. Inlet and
outlet pipe shall not be blocked by dirt and snow.
4. The fuel usage shall conform to the provisions on diesel fuel in GB 252.
5. Operating altitude requirements of heater:
When the heater operates at a height below 1500m, it can operate without limit.
Alpine pump kits must be added when the heater is operating at an altitude
above 1500m.
6. Control and safety devices
If the heater does not ignite within 90 seconds of starting fuel delivery, the starting
process will be repeated. If the heater does not ignite again within 90 seconds after
starting to deliver fuel, the fault will be shut down, that is, stop delivering fuel, fan will
be cooled for about 4 minutes. After more than the permitted number of startup
attempts and repeated failures, the controller will be locked. If the flame is automati-
1. Heating button
2. Heating operation display light (red)
3. Close button
4. Ventilation operation display light (blue
5. Ventilation button
6. Lowest temperature
7. Preselected temperature knob
8. Highest temperature
9. Temperature indicating arrow