Configurable safety system SAFEMASTER PRO - Fieldbus module
45
0265998 / 16.05.19 de / 101A
EtherNet/IP (UG 6955)
Process data mapping (Class 1 Connection)
Assembly instance 96h (Connection point O
→
T Consuming Instance)
Byte offset
Size
Name
0
USINT
Fieldbus input byte 0
1
USINT
Fieldbus input byte 1
2
USINT
Fieldbus input byte 2
3
USINT
Fieldbus input byte 3
O
→
T connection type: Point-to-point
Assembly instance 64h (Connection point T->O Producing Instance)
Byte offset
Size
Name
0
USINT
System Status
1
USINT
Reserved
2
USINT
Input status byte 0
3
USINT
Input status byte 1
4
USINT
Input status byte 2
5
USINT
Input status byte 3
6
USINT
Input status byte 4
7
USINT
Input status byte 5
8
USINT
Input status byte 6
9
USINT
Input status byte 7
10
USINT
Input status byte 8
11
USINT
Input status byte 9
12
USINT
Input status byte 10
13
USINT
Input status byte 11
14
USINT
Input status byte 12
15
USINT
Input status byte 13
16
USINT
Input status byte 14
17
USINT
Input status byte 15
18
USINT
Fieldbus input byte 0 feedback
19
USINT
Fieldbus input byte 1 feedback
20
USINT
Fieldbus input byte 2 feedback
21
USINT
Fieldbus input byte 3 feedback
22
USINT
Probe status byte 0
23
USINT
Probe status byte 1
24
USINT
Probe status byte 2
25
USINT
Probe status byte 3
26
USINT
OSSD status byte 0
27
USINT
OSSD status byte 1
28
USINT
OSSD status byte 2
29
USINT
OSSD status byte 3
O
→
T connection type: Point-to-point, Multicast
Assembly instance 05h (Configuration Data)
Set this instance to size 0
Supported trigger types: Cyclic
Содержание SAFEMASTER PRO UG 6951
Страница 55: ...Configurable safety system SAFEMASTER PRO Fieldbus module 55 0265998 16 05 19 de 101A DECLARATION OF CONFORMITY...
Страница 56: ...Configurable safety system SAFEMASTER PRO Fieldbus module 56 0265998 16 05 19 de 101A DECLARATION OF CONFORMITY...
Страница 57: ...Configurable safety system SAFEMASTER PRO Fieldbus module 57 0265998 16 05 19 de 101A NOTES www dold com...
Страница 58: ...Configurable safety system SAFEMASTER PRO Fieldbus module 58 0265998 16 05 19 de 101A NOTES www dold com...
Страница 59: ...Configurable safety system SAFEMASTER PRO Fieldbus module 59 0265998 16 05 19 de 101A NOTES www dold com...