DS-320SA
Instruction Manual
- 31 -
www.doallsaws.com
9.3
/1.PAR/ USER PARAMETERS
User (i.e. user-adjustable) parameters
pic: 9-6
Name
Description / Settings
Par. 1:
Initial band speed
The user can set the band speed for starting the saw up with the ON/OFF
button
default setting: 40
Par. 2:
BRP control current Setting the band drive current whose exceeding activates cutting travel
control
(the default level is the motor's rated value)
Par. 3:
Vice at the end of
the cut (s)
Setting the motion of the main vice at the cut end
0.0 - the vice remains closed
0.1
and more – the vice will be opening for the time set
default setting: 0.0
pic: 9-7
Name
Description / Settings
Par. 4:
Function of the
band at the end of
the cut
Setting the band motion at the cut end
0
– the band will stop in the bottom position
1
– the band will stop only after reaching the top position
Default setting: 1
Par. 5:
Function of the arm
at the end of the
cut
Setting of the arm motion at the cut end
0.0
– the arm remains in the bottom position when the cut is over
2.0
– the arm travels to the position set as Par. 8 when the cut is over
1.0
- the arm travels to the top position when the cut is over
3.0 -
the arm finishes the cut in the position set as Par. 9 and travels up to
the position set as Par. 8
10.0
0 and more – the arm travels up for 10 seconds or longer when the cut
is over.
Default setting: 1
Par. 6:
Switching off
hydraulics (s)
Time in which the hydraulics is automatically switched off if the machine is
idle
Default setting: 300