Digital Monitoring Products, Inc. | 1100T Wireless Translator Installation and Programming Guide
13
1100T Supported Zones
The supported zones per DMP panel are as follows:
DMP PANEL
AVAILABLE ZONES
ZONE RANGES
XTLplus and XTLtouch
99
1 - 99
XT50 with built-in receiver
48
11 - 14, 21 - 24, 31 - 34, 41 - 44, 51 - 54, 61 - 64, 71 - 74, 81 - 84, 80, 85 - 99
XT30 and XT50 (1100D Series)
32
11 - 14, 21 - 24, 31 - 34, 41 - 44, 51 - 54, 61 - 64, 71 - 74, 81 - 84
XR150 (1100X Series)
100
500 - 599
XR550 (1100X Series)
128
Any unused zone between 500 and 999
Non-DMP Sensor Supervision Time
Default Supervision time for Non-DMP sensors is 24 Hours. Additional supervision times
available include:
•
0 H
•
4 H - Fire, CO, or Supervisory zone type
•
12 H
Follow manufacturer guidelines for supervision times required on non-DMP sensors.