Digital Monitoring Products, Inc.     |     1100T Wireless Translator Installation and Programming Guide  

17

CERTIFICATIONS

FCC ID: CCKPC0225
IC: 5251A-PC0225

Intertek (ETL Listed)

 

UL 864  

Control Units and Accessories for Fire Alarm Systems

 

UL 985  

Household Fire Warning System

 

UL 1023  

Household Burglar Alarm System Units

 

UL 2610  

Commercial Premises Security Alarm Units and Systems

ORDERING INFORMATION

1100T  

Wireless Translator

1100TF  

Wireless Translator with 24-hour standby battery  

 

 

for Fire Applications

Содержание 1100T

Страница 1: ...INSTALLATION AND PROGRAMMING GUIDE 1100T Series Wireless Translator ...

Страница 2: ......

Страница 3: ...nslator 6 Program Zone Information 6 Mount the Translator 8 Walk Test 9 Additional Information 11 Replace the Battery 11 Status LEDs 12 1100T Supported Zones 13 Non DMP Sensor Supervision Time 13 TABLE OF CONTENTS Compliance Listing Specifications 14 Commercial Fire 14 Product Specifications 15 Patents 15 Accessories 16 Certifications 16 Intertek ETL Listed 16 Ordering Information 17 FCC Informati...

Страница 4: ......

Страница 5: ... with transmitters that operate at various MHz such as Interlogix Honeywell 5800 2GIG and DSC The translator operates with a wireless connection to a DMP receiver on a DMP panel and is available as an 1100T or 1100TF version Learn Feature Transmitters that have been learned into the 1100T are able to send supervision and low battery messages to the panel Tampers The translator is equipped with a c...

Страница 6: ...ss Translator is not compatible with systems using the 1100R Wireless Repeater Interlogix 319 5 MHz Honeywell 5800 345 MHz 2GIG Series 345 MHz DSC 433 MHz Encryption from 1100T to DMP Receiver requires panel Version 211 or higher and Receiver Version 301 or higher Remote Link Version 2 11 3 2 21 or higher Full Compatibility Guide For a full list of compatible non DMP products see the 1100T Wireles...

Страница 7: ... 1100T Wireless Translator Installation and Programming Guide 3 TRANSLATOR FEATURES Figure 1 Product Features BAT 12V Tamper Switch Survey LED MODEL 1100T Non DMP Antenna DMP Antenna Charge Status LED Green Status LED Red Status LED ...

Страница 8: ... translator device number The 372 500 W power supply must be located within 100 feet of the translator using 22 AWG wire Use the following steps to connect it 1 With the cover removed connect the positive wire to the positive terminal on the translator 2 Connect the negative wire to the negative terminal on the translator 3 Plug the power supply into a wall outlet not controlled by a switch 1 PRE ...

Страница 9: ... 2 16 3 Select UNUSED to enter a name for the device After naming the device press CMD XR Series Panels Press the fourth select key or area to change the device type Press CMD until TLR is displayed and select that for the translator XT Series Panels At 1100T NO YES select YES and press CMD 4 Enter the Serial number 5 At 1100T FREQ press any select key or area to select the non DMP system Default ...

Страница 10: ...on is confirmed or faulty Confirmed If communication is confirmed for each press or release of the tamper switch the LED blinks immediately on and immediately off Repeat this test 5 times to confirm ten separate consecutive LED blinks Any indication otherwise means proper communication has not been established Faulty If communication is faulty the LED remains on for about 8 seconds or flashes mult...

Страница 11: ...has received the tamper signal the serial number will display Note If programming a sensor with multiple contacts use the appropriate serial number See LT 0705 1114 Wireless Four Zone Expander Installation Guide for programming instructions 7 Once the serial number is entered press CMD 8 At the transmitter contact display press a select key to choose from contact 1 2 3 or 4 Default is 1 Note If pr...

Страница 12: ...objects to protect the unit from damage due to tampering or the elements Mount the translator a minimum of 4 feet from any wireless panels or receivers It is necessary to remove the PCB when installing the enclosure Refer to Figure 2 in the following steps 1 With the cover removed use the included 6 screws to secure the 1100T to the wall 2 Use one of the provided screws to secure the wall tamper 5...

Страница 13: ...en you have selected all the zone types you want for testing press CMD Note For the purpose of the Walk Test do not select WLS or PIR These options are not compatible 4 Select BELL This option is for when a zone under test faults This option allows the panel bell and or burglary bell and or fire bell to turn on and then off each time a zone is tripped NO Select for no bell output action during Wal...

Страница 14: ...nter 8144 WALK 3 Select STD to test all programmed zones 4 Once in the Walk Test walk around and trip each protective device Continue tripping devices until the entire system is tested Each time a selected zone trips the keypad buzzes and the bell rings for two seconds Each time a FI FV SV or CO zone trips a Sensor Reset occurs 5 Press the select key or area directly below END to stop the Walk Tes...

Страница 15: ...eplace the Battery DMP recommends replacing the battery every three years 1 Open the translator housing to expose the inside of the 1100T 2 Remove the PCB board 3 Unplug the battery connector then remove the old battery 4 Connect the battery connector 5 Snap the PCB Board back in place 6 Snap the cover back on the 1100T ...

Страница 16: ...0T is in sync with the DMP 1100 wireless receiver Green OFF and red ON means the 1100T is not in sync with the receiver If the green is OFF and red flashes every 1 4 second the 1100T should be power cycled manually The charge status LED is hardware controlled and will be ON when the battery is connected and charging It will be OFF when the battery is connected and fully charged Flashing once a sec...

Страница 17: ...4 31 34 41 44 51 54 61 64 71 74 81 84 80 85 99 XT30 and XT50 1100D Series 32 11 14 21 24 31 34 41 44 51 54 61 64 71 74 81 84 XR150 1100X Series 100 500 599 XR550 1100X Series 128 Any unused zone between 500 and 999 Non DMP Sensor Supervision Time Default Supervision time for Non DMP sensors is 24 Hours Additional supervision times available include 0 H 4 H Fire CO or Supervisory zone type 12 H Fol...

Страница 18: ...e enclosure by removing the two screws from the outlet and inserting them through the back of the enclosure Install conduit fittings connect wiring and install the power supply Secure the enclosure cover with two screws See Figure 3 Conduit ES501 372 500 W 1100TF installed on backbox Figure 3 Power Supply with Enclosure Wiring Battery The 9800BAT2400 provides 24 hour standby operation for Commerci...

Страница 19: ...2 VDC 31 mA Standby Battery 1100T Voltage 3 7 VDC Type Lithium Polymer rechargeable Capacity 800 mAh Standby 4 hours 1100TF Voltage 3 7 VDC Type Lithium Polymer rechargeable Capacity 2400 mAh Standby 24 hours Frequency Range 905 924 MHz Dimensions 5 50 W x 3 75 H x 1 00 D 13 97cm W x 9 53 cm H x 2 54 cm D Temperature 32 120 F Humidity 93 ...

Страница 20: ...acement rechargeable battery 8 pack 9800BAT2400 8 Battery for Commercial Fire 24 hour Standby 505 12 12 VDC Power Supply 372 500 W Plug In DC Power Supply ES501 Transformer Enclosure 4 25 W x 5 625 H x 2 5 D inches ES502 Transformer Enclosure 4 25 W x 5 625 H x 3 75 D inches PATENTS U S Patent No 7 239 236 DMP Wireless Sensors ...

Страница 21: ...ntertek ETL Listed UL 864 Control Units and Accessories for Fire Alarm Systems UL 985 Household Fire Warning System UL 1023 Household Burglar Alarm System Units UL 2610 Commercial Premises Security Alarm Units and Systems ORDERING INFORMATION 1100T Wireless Translator 1100TF Wireless Translator with 24 hour standby battery for Fire Applications ...

Страница 22: ...e designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipme...

Страница 23: ...desired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctio...

Страница 24: ...LT 2243 1 01 21132 2021 Digital Monitoring Products Inc ...

Отзывы: