Program Device Setup
The translator must first be programmed as a device in Device Setup. Zones should
be programmed in Zone Information.
1.
Go to
DEVICE SETUP
and press
CMD
.
2. At
DEVICE NO
, enter the desired device number for the 1100T. Available addresses:
•
XT30, XT50, XTL Series, or XR150: 2-8
•
XR550: 2-16
3. Select
*UNUSED*
to enter a name for the device. After naming the device,
press
CMD
.
•
XR Series Panels:
Press the fourth select key or area to change the device type.
Press
CMD
until
TLR
is displayed and select that for the translator.
•
XT Series Panels:
At
1100T? NO YES
, select
YES
and press
CMD
.
4. Enter the Serial number.
5. At
1100T FREQ
, press any select key or area to select the non-DMP system.
Default is
HWL
(Honeywell).
6. At
SUPRVSN TIME
, select the supervision time required for the 1100T. DMP
default supervision time is
240
minutes.
7. Press
CMD
and then the Back Arrow to exit Device Setup.