INPut:GENLock:INPut
Command for selecting the genlock input. Possible selections are:
Input:
Description
:
A
A
B
B
A B
A-B, i.e. loop through
INTernal
Internal
When selecting a new input, the system for that particular input will apply.
Example:
INP:GENL:INP A B
select input A/B as the genlock signal
INP:GENL:INP?
response: A B
INPut:GENLock:SYSTem
Command for selecting the genlock system. Possible selections are
System:
A, B & A_B
SDI:
Description:
PALBurst
X
X
PAL burst lock
NTSCburst
X
NTSC burst lock
SYNC625
X
625 sync lock
SYNC525
X
525 sync lock
SDI625
625/50 lock
SDI525
X
525/59.95 lock
F358MHz
X
3.58 MHz lock
F443MHz
X
4.43 MHz lock
F5MHz
X
5 MHz lock
F10MHz
X
10 MHz lock
Note:
When the input has been selected as Internal or Internal2, issuing this command will result in an error, namely:
-200,
“Execution error”. This error will also occur if selecting a system which is invalid for the active input.
Example:
INP:GENL:SYST
F358MHz
set
system to 3.59 MHz
clock
INP:GENL:SYST?
response: F358 MHz
INPut:GENLock:DELay
Command to set the delay for the genlock input. The delay is defined by
three param- eters
<
Field
>
,
<
Line
>
,
<
HTime
>
where
<
Field
>
sets the field offset,
<
Line
>
sets the
line offset and
<
HTime
>
sets the horizontal time in ns, i.e.
•
HTime(PAL)
<
64000.0 ns
•
HTime(NTSC)
<
63492.1 ns
Note:
It is not possible to select timing when the genlock system is 3.58 MHz, 4,43 MHz, 5 MHz,
or 10 MHz or the input is set to internal or internal2. This will result in an execution error, namely: -