PT5300 |
27
• When the new format appears on the display, then move the cursor to SAVE and press E to change the
signal format.
• If no change is desired, move the cursor to ESC and press
.
Leaving the function takes you back to the GENLOCK menu.
Note:
Now the selected genlock system (A, B, Loop-through or Internal) is configured. If the input for this system has
not been activated, select OK in the GENLOCK menu and press E
Which signals are available to the different genlock inputs depends upon the type of genlock edited.
Genlock signals available for A, B, and A-B:
•
PAL Burst
•
NTSC Burst
•
625 Sync
•
525 Sync
•
4.43 MHz
•
3.58 MHz
•
5 MHz
•
10 MHz
Genlock signals available for GPS:
•
525/59.94
•
626/50
Note:
No Genlock system or Timing can be selected when Genlock Input is set to Internal or one of the continuous
wave signals.
To change the genlock timing for the input selected, select TIMING in the GENLOCK menu.
SUBMNU:GENLOCK/TIMING, edit delay
V:<+0>H:+123 T:+00123.4 SAVE ESC
Operation:
• Use the and buttons to select V, H, or T
• Then use the
and
buttons to select the value desired. Changes to the timing are instantaneous, i.e. any
changes are reflected immediately in the output signal.
The timing can be adjusted by coarse or fine adjustment parameters. The coarsest adjustment is the Field (V), the
finest is Time (T), and Line (H) is between. The T value is in nanoseconds. The timing resolution depends upon the
type of signal used for genlock.
• When the desired delay setting appears in the display, move the cursor to SAVE and press E
• If no change is desired, move the cursor to ESC and press
.
Leaving the function takes you back to the GENLOCK menu