GB
10
CROSS30 - IP1777
1. TECHNICAL DATA
CROSS30E
CROSS30
Power supply
400 V~ 50 Hz
400 V~ 50 Hz
Absorption
2,1 A
2,1 A
Motor power
550 W
550 W
Thrust
3000 N
3000 N
Door speed
0,16 m/s
0,16 m/s
Max run
20 m
-
Max door weight
3000 kg
3000 kg
Service class
5 - HEAVY DUTY
5 - HEAVY DUTY
Intermittence
S3 = 100%
S3 = 100%
Temperature
-20 °C / +55 °C
-20 °C / +55 °C
Degree of protection
IP45
IP45
Control panel
E1T (incorporated)
-
2. REFERENCE TO ILLUSTRATIONS
The given operating and performance features can only be
guaranteed with the use of DITEC accessories and safety
devices.
2.1 Standard installation references (fig. 1)
[1] Radio
[2] Flashing light
[3] Key selector
[4] Geared motor + control panel
[5] Photocells
[6] Sensitive edge
[7] Opening and closing stop
[8] Connect power supply to an type-approved omnipole
switch with a contact opening gap of no less that 3 mm
(not supplied)
Connection to the grid is made with independent channels
and separated from the connections to the control and
safety devices.
2.2 Geared motor references (fig. 3)
[9] Geared motor
[10] Cable fitting
[11] Housing
[12] Terminal board
[13] Release screw
[14] Pinion module 6
[15] Magnetic limit switch
[16] Base plate
[17] Limit switch bracket
[18] Limit switch of release access door
3. INSTALLATION
Unless otherwise specified, all measurements are expressed
in millimetres (mm).
3.1 Preliminary checks
Check the stability of the wing (derailing and lateral falls) and
the sliding wheels and that the upper guides do not cause any
friction.
The sliding track must be securely anchored to the ground and
fully exposed along its full length.
It must be perfectly smooth so as to avoid jamming of the gate.
Provide opening and closing stops.
Note: make sure that the gate can not exit the sliding guides
and fall.
If the gate has slits, make sure they are covered to prevent
shearing points.
Safety device should be installed at the end of the wing to reduce
the collision force.
3.2 Base plate position
-
Insert the anchor ties onto the base plate [16] and fix them
with the supplied nuts.
-
Lay a concrete foundation with buried anchoring brackets
and the base plate, making sure that it is pefectly level and
smooth, complying with the measurements shown in figure
(the side to be placed in contact with the ground is marked
on the base plate). If a concrete foundation is already
available, secure the motor by means of appropriate
dowels (not supplied) capable of withstanding a pushing
force of at least 3000 N.
Warning: the base plate is smaller than the gear motor
base. Check the base plate sides are free [*].
X
20
160