28
•
Hold the SAVE “MEM” key (T2) down for at least
2
consecu-
tive seconds.
T2
T ≥ 2 s
•
The program in use has now been completed successfully. To
confirmation the above, the control panel of the welder performs
a short operation of MACHINE CHECK (all of the LED stay lit
simultaneously so as to verify their actual operation), the gen-
erator itself starts, having memorised the new settings and is
again ready to weld.
4 - PRE-SETTING
Before welding it is possible to set the following parameters:
D1
T1
E1
WIRE SPEED
Example: WIRE SPEED
Press the PARAMETER SELECTION - A key (T1) until the LED
that corresponds to the WIRE SPEED switches on. Turn the EN-
CODER - A knob (E1) to change the value shown on the PARAM-
ETER DISPLAY - A screen (D1).
D2
T4
E2
ELECTRONIC INDUCTANCE
WELDING VOLTAGE
Example: ELECTRONIC INDUCTANCE
Press the PARAMETER SELECTION - V key (T4) until the LED
that corresponds to the ELECTRONIC INDUCTANCE switches
on. Turn the ENCODER - V knob (E2) to change the value shown
on the PARAMETER DISPLAY - V screen (D2).
5 - WELDING
During the welding the display shows:
•
PARAMETER DISPLAY screen - A (D1)
D1
WELDING CURRENT
WIRE SPEED
- WELDING CURRENT(
): the measured value of the current
of what is being welded.
- WIRE SPEED (
): the value previously set.
•
PARAMETER DISPLAY screen - V (D2)
D2
ELECTRONIC INDUCTANCE
WELDING VOLTAGE
- WELDING VOLTAGE (
): the measured value of the voltage
of what is being welded.
- ELECTRONIC INDUCTANCE (
): the value previously set.
During the welding the operator can change the following param-
eters:
•
WIRE SPEED (
).
•
WELDING VOLTAGE (
).
•
ELECTRONIC INDUCTANCE (
).
•
SPECIAL FUNCTIONS “Fx”.
6 - HOLD
This function automatically starts itself at the conclusion of every
welding operation and it is indicated to the operator by means of a
flashing light of the HOLD FUNCTION LED for a specific amount
of time.
Once the welding has been terminated, for about
15
seconds, both
the DISPLAYS should show the same values of the parameters
during the welding.
In this phase the displays show:
•
PARAMETER DISPLAY screen - A (D1)
D1
WELDING CURRENT
WIRE SPEED
- WELDING CURRENT (
): the last current value measured.
- WIRE SPEED (
): the value previously set.
•
PARAMETER DISPLAY screen - V (D2)
D2
ELECTRONIC INDUCTANCE
WELDING VOLTAGE
- WELDING VOLTAGE (
): the last voltage value measured.
- ELECTRONIC INDUCTANCE (
): the value previously set.
Содержание DIX PI GO 2006.M