20
D1
D2
E1
2) Push the
PRG
key (T5), and the display will show the error
code under DISPLAY PARAMETERS - A (D1), and the num-
ber of times under DISPLAY PARAMETERS - V (D2). For the
code error, see the list contained in the “Error Conditions” par-
agraph.
D1
D2
T5
3) Rotate the ENCODER - V (E2) knob to scroll the list.
4) To go back to the
SEtUP
menu, push the SAVE “MEM” (T2)
key.
T2
5) To exit the
SEtUP
menu, push the SAVE “MEM” (T2) key
again.
T2
TEST
This configuration allows the operator to check that some func-
tions of some devices.
1) Rotate the ENCODER - A (E1) knob, until both the displays
(D1-D2) read
tESt
.
D1
D2
E1
2) Push the
PRG
key (T5), and the display will show the param-
eter to be checked under DISPLAY PARAMETERS - A (D1),
and the set-ting under DISPLAY PARAMETERS - V (D2).
D1
D2
T5
3) Rotate the ENCODER - A (E1) knob to select the device to be tested.
(
GAS
[
solenoid valve
],
Mot
[
wire feeder motor
],
FAn
[
fans
]
and
H2o
[
cooling unit, only if fitted
])
4) Rotate the ENCODER - V (E2) knob clockwise to go from the
oFF state to the on state, which activates the device and al-
lows the user to check it is working.
D2
E2
5) To go back to the
oFF
state, rotate the ENCODER - V (E2)
knob anticlockwise.
6) Push the SAVE “MEM” (T2) key to go back to the
SEtUP
menu.
T2
7) To check another device, repeat steps 2, 3 and 4.
8) To exit the
SEtUP
menu, push the SAVE “MEM” (T2) key
again.
T2
Содержание DIX PI GO 2006.M
Страница 13: ...13 2101AC73...