11.
Measurement of the pressure
-
connect the pressure gauge to the measuring point
-
the max. pressure for oil at operating temperature (40 - 60 °C)
is 21 - 21.5 MPa (210 -215 bar)
-
for turning 8 MPa (80 bar)
-
for extension of telescope 7 MPa (70 bar)
-
if you have to readjust the pressure, secure the new setting
with a seal.
12.
Check the operating controls on the platform.
-
check the overall condition of the electric appliances inside the box and spray with moisture
repellent, if necessary.
-
check the cables and the tightness of the cable clamps.
-
test the sound signal, emergency stop and emergency descent functions.
-
test all movements
13.
Warning signs and adhesives
-
make sure that all warning signs and adhesives are legible, replace if necessary.