OPERATOR’S MANUAL
with Maintenance Information
Maintenance
53
B-7
Test the Drive Brakes
DINGLI requires that this procedure be
performed every 250 hours or quarterly,
whichever comes first.
Proper brake action is essential to safe
machine operation. The drive brake function
should operate smoothly, free of hesitation,
jerking and unusual noise.
Hydraulically-released individual wheel brakes
can appear to operate normally when not fully
operational.
Perform this procedure with the machine on a
firm level surface that is free of obstructions,
with the platform extension deck fully retracted
and the platform in the stowed position.
1 Mark a test line on the ground for
reference.
2 Turn the key switch to platform control.
Turn the ground red Emergency Stop
button clockwise to the on position. Pull
out the platform red Emergency Stop
button to the on position.
3 Lower the platform to the stowed position.
4 Press the drive function select button.
a
a drive function select button
5 Choose a point on the machine; i.e.,
contact patch of a tire, as a visual
reference for use when crossing the test
line.
6 Bring the machine to top drive speed
before reaching the test line. Release the
function enable switch or the joystick when
your reference point on the machine
crosses the test line.
7 Measure the distance between the test line
and your machine reference point.
⊙
Result: The machine stops within the
specified braking distance. No action
required.
¤
Result: The machine does not stop within
the specified braking distance. Note: The
brakes must be able to hold the machine
on any slope it is able to climb.
8 Replace the brakes and repeat this
procedure beginning with step 1
Braking distance, maximum
High range on paved surface
61cm
±
30cm
Содержание S06-E
Страница 2: ......
Страница 4: ......
Страница 15: ...OPERATOR S MANUAL with Maintenance Information Decals 11 ...