![Dinamica Generale DG8000 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/dinamica-generale/dg8000/dg8000_operators-manual_2505533031.webp)
Configuration
INDICATOR DG8000 RevB0
29
E
N
GL
IS
H
167
Save Unload
Total
YES..NO
(YES)
Enable/Disable the saving the modifies made to
the unloads before of the execution
168
WiFi Report
Confirmation
YES..NO
(NO)
Enable/Disable the requirements to press a key
when you see the report at the end of the WiFi
communication.
177
Max Load
Runtime
0…240
(0)
It indicates the maximum time (expressed in
minutes) where the DG8000 Indicator will show
one Component inside one loading execution.
If this parameter is set on 0 , there is no limit
about time
178
Load
updated by
Unload
YES..NO
(NO)
This parameter enables the automatic
recalculation of the loading, if linked Unloading
Program has been changed
179
Save Load
Head
Number
YES..NO
(YES)
This parameter enables the automatic saving of
the cow number in order to show it again during
the next loading execution.
180
Save unload
head number
YES..NO
(YES)
This parameter enables the automatic saving of
the cow number in order to show it again during
the next unloading execution.
181
Enable
RealTime
IRM Saving
YES..NO
(NO)
YES: When the reset key is pressed from the
execution of a program, the execution is saved
regardless of whether it is finished or not.
NO: No operation is saved until the program exit
confirmation.
182
GPRS Retry
1..50
(5)
It indicates the number of retry answer wait of the
modem after a request.
183
Normalized
variation
YES..NO
(NO)
Parameter to define how the percentage change
value is shown in the load or unload screens;
Parameter NO, no variation 0%
Parameter YES, no variation 100%
185
DTM
Authenticatio
n
YES..NO
(NO)
This parameter enables the confirm request by
the operator during the receipt of a message via
GPRS.
YES: the message “ENTER to accept or RESET
to reject.” Appears.
Содержание DG8000
Страница 1: ...OPERATOR S MANUAL DG8000 Feeding Monitoring...
Страница 2: ......
Страница 8: ...General Information INDICATOR DG8000 RevB0 6 Power and sensor connection system without junction box...
Страница 10: ...General Information INDICATOR DG8000 RevB0 8 Accessories connection system with 4 sensor connectors...
Страница 16: ...General Information INDICATOR DG8000 RevB0 14 Display connection available for UNIVERSAL BOX and for SLIM BOX...
Страница 17: ...General Information INDICATOR DG8000 RevB0 15 ENGLISH Connection front loader side...
Страница 105: ...dinamica generale S p A via Mondadori 15 46025 Poggio Rusco MN Italy Cod 985 0122 Rev B0...