![Dinamica Generale DG8000 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/dinamica-generale/dg8000/dg8000_operators-manual_2505533028.webp)
Configuration
INDICATOR DG8000 RevB0
26
15
Manual
Component
Selection
LOAD
UNLOAD
BOTH
NONE
(BOTH)
When executing programs, it is not possible to
carry out what follows, if not enabled:
Scrolling the Components with the
↑
or
↓
;
Confirm a partial execution of a Component by
pressing ENTER.
It is possible enable this function during the
loading (for the component), the unloading (for
the unloading point), for both or for none.
16
Stabilization
Time
0..100 sec
(0)
Time to wait in order to have a stabilization of the
weight at the end of the load of every Component
during the execution of loading Recipes
17
Language
(English)
Select the desired language
English, Italian, Spanish, German, French,
Portuguese, Danish, Dutch, Polish, Russian,
Hungarian, Czech, Swedish, Turkish, Chinese
19
Multiple Print
YES/NO
(NO)
If enabled, it allows you to manage a number of
multiple printouts as specified in the parameter
“Repeated Print Number”.
20
Repeated
Print Number 1..99
(1)
Repeated print Number.
This is a default value if the number of printouts
is shown on the screen. It is modifiable in the
sections where it is listed.
24
Modify Name Sì..NO
(Sì)
Refer to the menu (To set/modify the strings) in
the SYSTEM CONFIGURATION.
If enabled, the operator can have access to the
strings management menu where it is possible to
change the names of components/unloading
points.
25
Maximum
Value
100..999999
(15000)
Overloading value.
If this value is exceeded, the system will activate
an overload alarm (over range).
The maximum value that can be set might be
limited to factory settings, set by the
manufacturer of the machine on which Dinamica
Generale’s indicator is installed.
26
Local Prog.
Modify
Abilitato/
Disabilitato
(Abilitato)
If not enabled, it is not possible to enter the
programming menu for loading/Unloading
Programs. In addition to that, it is not possible to
enter the editing menu with names of
Components and Unloading Points.
28
Mixing Timer
Status
Abilitato/
Disabilitato
(Abilitato)
If it is not enabled, it is not possible to set the
mixing time at the end of the execution of a
Recipe.
29
Mixing Timer
Value
0..50 min
(0)
Mixing time at the end of the execution of a
Recipe.
33
Filter
Threshold
1..30000
(30000)
Not used.
Содержание DG8000
Страница 1: ...OPERATOR S MANUAL DG8000 Feeding Monitoring...
Страница 2: ......
Страница 8: ...General Information INDICATOR DG8000 RevB0 6 Power and sensor connection system without junction box...
Страница 10: ...General Information INDICATOR DG8000 RevB0 8 Accessories connection system with 4 sensor connectors...
Страница 16: ...General Information INDICATOR DG8000 RevB0 14 Display connection available for UNIVERSAL BOX and for SLIM BOX...
Страница 17: ...General Information INDICATOR DG8000 RevB0 15 ENGLISH Connection front loader side...
Страница 105: ...dinamica generale S p A via Mondadori 15 46025 Poggio Rusco MN Italy Cod 985 0122 Rev B0...